BMS watchman

Electrodacus SBMS0 · GitBoat v10.5 A4 · Bus: none · USB isolator not fitted

Status notes
  1. BMS box diagram Decided

    BMS box diagram v10.5. Both shunts stay on the positive side. The box is bolted to the outside of a long side wall of the battery box, never inside it. Which side is open. Charging is always on (Electronics 6.7). Channel 8 is spare.

  2. Monitor setup Decided

    Battery Monitor Setup v10.5: Device Settings USART ON, 115200, and end-of-charge voltage 3.44 V. System Settings Sheet v10.5 does not state those numbers.

  3. Box plan Decided

    BMS box plan. The box is bolted to the outside of a long side wall of the battery box, never inside it. Both shunts stay on the positive side.

WATCHMAN Electrodacus SBMS0Electrodacus SBMS0reads, controls nothinggreen plug: shunts on 1 to 4, XT1 on 15, 16cell socket: new 12-pin ribbon WiFi / USB add-onWiFi / USBmicro USB add-on Winford BRK2X6-L-DIN ribbon breakoutWinford BRK2X6-L-DINribbon to screw terminals · DIN railW0 on 1, 2 + drain · W8 on 10 to 12 JK-B2A8S balancerJK-B2A8S balancer2 A active · talks to nothingown power pair: V- on W0, V+ on W8 Butt splices x9Butt splices x9JK harness to its 18 AWG 10-coreB0 + V- at W0 · B8 + V+ at W8 watches only - no charger wiring Entry 4, USB telemetry out to hub box A1a by S port c. No isolator on this lead.4 · USBS port c Entry 3, the two positive-side shunt sense pairs3 · Shunts300 A bat + · 100 A solar + Entry 1a, the SBMS0 nine taps plus the XT1 pair on the 22 AWG 12-core shielded, alone in its PG91a · SBMS0 tapsPG9 · 12-core + XT1 Entry 1, the JK nine taps on the ENERJOUR 18 AWG 10-core, alone in its PG13.51 · JK tapsPG13.5 · 18 AWG 10-core micro USB 2 sense pairs XT1 pair 12-core shielded 11-pin plug JK's 9 taps · 18 AWG 10-core no entry 6: the DS18B20 chain skips this box power USB analog