From Electronics and Wiring Plan v10.2 (sec 6.7, Appendix A3, A4, A9) and Battery Box Building Guide v10.2 Part 8. Drawn 2026-09-07, rev 2026-10-08. The table and notes are on page 2.

USB HUB BOX, BY PI A StarTech hub on Pi A's 5 V; its lead on to Pi A, no isolator BMS BOX bolted to the battery box's aft wall entry 3 sense pairs ELECTRODACUS SBMS0 the watchman: reads, controls nothing shunts: pins 1 to 4 cell socket, 12-pin XT1: pins 15 and 16 WiFi/USB add-on entry 4, micro USB pack data, required new 12-pin ribbon, about 8 in 112 Winford BRK2X6-L-DIN, terminals 1 to 12 NO CHARGER WIRING: MONITORING ONLY no EXTIO4 pause, no VE.Direct cables, no bypass 9 BUTT SPLICES V- with B0 at W0 V+ with B8 at W8 JK-B2A8S BALANCER 2 A active balancing; talks to nothing plug: B0 to B8, V-, V+ entry 1 SBMS0 taps, 12-core, shielded JK taps, 18 AWG 10-core DS18B20 chain, out by its own PG7 (entry 6) entry 6, PG7 CENTRAL NODE temp chain in (entry 18) BATTERY BOX 32 cells, 8 groups of 4, 24 V group 8 (+)group 7group 6 group 5group 4group 3 group 2group 1 (−) W8W7W6W5W4 W3W2W1W0 2 perjoint,ownposts,fused entry 3 XT1 thermistor, held on a cell face DS18B20 temperature probe chain + post − post CLASS T 300 A 300 A SHUNT from the + solar bar 100 A SHUNT + 400 A bar battery −: plain cable to the − 400 A bar Both shunts sit on the + side, on the main bus board; only their thin sense wires go up to entry 3, one pair per shunt, each wire on a 30 AWG fuse link at the shunt, a cover on each shunt.

What each link is, and why

LinkWhat it isWhy
Battery box (its entry 3) to BMS box (entry 1)One bundle: 18 tap wires (W0 to W8 twice), each on its own ring and 30 AWG fuse link at the battery, the two wires of each joint on two posts. The SBMS0's nine and the XT1 pair on 11 cores of the 22 AWG 12-core shielded cable (shield grounded at this box only, at W0); the JK's nine on its 18 AWG 10-core. Plus the DS18B20 chain, sleeved so the gland seals on one round sleeve. Open: the gland, PG13.5, PG16 or PG21, once the sleeved bundle is measured. No gas sensor lead.The SBMS0's taps read the 8 group voltages. The JK pushes up to 2 A through its own taps; on shared wires that would put tens of mV of error into the SBMS0's readings.
SBMS0 to the breakout board, insideA new 12-pin ribbon, about 8 in, to the Winford BRK2X6-L-DIN on the DIN rail; terminal n = ribbon wire n. W0 on 1 (jumper 1 to 2, shield drain on 2), W1 to W7 on 3 to 9, W8 on 10 (jumpers 10 to 11, 11 to 12). At most two wires under one screw.The SBMS0's own ribbon is never cut or lengthened (never longer than its 6 ft).
Shunts to BMS box (entry 3)One twisted pair per shunt (stranded Cat6, ferrules) on the green plug: battery shunt to pins 4 and 3, solar shunt to 2 and 1. Both shunts on the + side of the main bus board. Each wire on a 30 AWG fuse link at its shunt; a cover on each shunt. Sense leads only.The SBMS0 reads a shunt only with 4 to 76 V on it: on the − side it would read nothing.
BMS box to the USB hub box beside Pi A (entry 4)Micro USB lead from the WiFi/USB add-on, tied down outside the plug, into the StarTech hub. Required. No USB isolator: the hub runs on Pi A's own 5 V.The battery percentage comes from this stream: the SBMS0 shunt is the only current sensor aboard. A quiet stream raises an alert.
BMS box to the central node (entry 6)The temperature chain, connected to neither board: in with the bundle by entry 1, out by its own PG7 (entry 6 in Appendix A4) to central node entry 18.The six pack probes carry the battery trip: 150 F, or a 10 F rise in five minutes, isolates the bank.
BalancerIts 11-pin plug: B0 to B8 plus its own power pair, V- and V+ (10 to 40 V), joined to its 10-core cable by butt splices; V- shares the W0 splice, V+ the W8 splice. Set up by phone over Bluetooth: LiFePO4, 8 cells.It only evens out the groups: no data, no control, no wire to the node or the Pi.

Where it goes. Bolted through the battery box's aft wall on the minus side, opposite the main fuse, at mid-height or above, never on a long side wall: four 1/4 in stainless bolts, each bedded in sealant (Battery Box Building Guide Parts 4 and 8). Glands face down, each cable with a drip loop.

Monitoring only. No wire leaves this box to a charger, relay or load. No CAN and no RS-485. The only data wire is the USB lead to the hub box beside Pi A, which is required. The charge limits live in the five MPPTs' own lithium profiles. Nothing stops charging in the cold automatically: Pi A alerts shore below 33 F on any pack probe, and shore can send the 5-day charging stop (relay channel 8).

Back to the atlas