USB hub box (A1a)

The small box beside Pi A that holds the USB hub and everything plugged into it, the 12 V supply for the two weather sensors, and the ends of the wing cable. The MOTU M2 is in its own box; only its USB lead comes in here. Page 1 shows roughly where each part sits, page 2 the wiring, page 3 every wire from and to. Not to scale.

BoatBoat 1, Prime Ranger
Doc setv10.4
DrawnOct 20, 2026 · Updated 2026-11-01
Home guideElectronics plan A1a; Box Wiring Sheet A1a

Where the parts sit, lid off

NOT TO SCALE · OPEN: THE BOX’S MAKE AND SIZE
SIDE WALL, SEEN FROM OUTSIDE · NONE ON TOP · DRAWN ABOVE THE BOX FOR ROOM T S · split gland, 5 ports PG7, hub 5 V c SBMS0 · e MOTU lead d AIS coax · a to Pi A · b wing cable BOX: ABOUT 10 x 8 x 4 IN OR BIGGER, IP65 OR IP67 PLASTIC, WITH A MOUNTING PLATE · NOT TO SCALE OPEN: THE BOX’S MAKE AND SIZE (BUILT, NOT LOGGED); MIKE’S WORD SETTLES IT YRDZXG 24 to 12 V, potted screwed to the plate StarTech 10-port USB hub on M3 nylon standoffs; 5 V terminal at the left end, its own USB lead at the right end, ports facing down plug space: keep about 3 in clear below the ports for plugs and cable bends CAN adapter SH-C30G tied down SDI-12 USB adapter The MOTU M2 is not in this box: it has its own box (Mike). Its USB lead comes in by S port e to a hub port. dAISy 2+ BNC to the jumper Coax jumper loops between the dAISy and gland S; tie the coax to the plate so its weight never hangs on the BNC socket. DIN RAIL, ABOUT 10 IN TB1 · 9 terminals 24 V, 12 V, SDI-12 Waveshare 2-ch RS-485 clips on the rail USB lead up to the hub TB2 · 9 terminals wing cable desiccant pack BOTTOM WALL, SEEN FROM BELOW · EACH GLAND UNDER WHAT IT FEEDS 1 2 3 4 5 Entries Side wall (leads that keep plugs) S split gland, 5-port, M30 thread, 1-3/16 in hole T PG7, 1/2 in hole: hub 5 V Bottom (bare wire ends) 1 PG9: 24 V in, 16/2 B 4-port split gland: 2 BaroVUE, 3 HygroVUE, 4 SBE 45 line, 5 DO sensor line Wing cable: by S port b PG9 5/8 in, split glands 1-3/16 in. 16/2 is oval: fill that gland with sealant. Where it goes Beside Pi A, bottom wall down, within reach of Pi A’s USB lead and the 5 V lead. The FTDI cables are 6 ft: the wet lab box within about 5 ft. No vent. Nothing in this box goes to the lightning copper.

Wiring

DOT = JOINED · LINES CROSSING WITH NO DOT DO NOT TOUCH · GRAY BAR = TERMINALS BRIDGED
SIDE WALL (S, T; NONE ON TOP) BOTTOM WALL T T · PG7: hub 5 V lead in 2-core, from Pi A entry 12, its 3 A fuse is in the Pi A box c e d a b S · Altelix PG25 5-port split gland (on hand): plugs stay on c SBMS0 lead in, from the BMS box · e MOTU M2 lead in, from its own box d AIS antenna coax in, PL-259 on · a hub lead out, to Pi A USB 1 b wing cable in (shielded Cat6 on hand, about 5 ft, plugs cut off) StarTech USB210AIND, 10-port hub on M3 nylon standoffs · plugs zip-tied · two ports spare 5 V in + − red +, black − SBMS0 MOTU dAISy 2+ BNC on top jumper hub lead wing cable DSD TECH SH-C30G USB to CAN · hub port · 120 ohm ON GNDCAN_HCAN_L SDI-12 USB adapter BaroVUE at address 0 HygroVUE at address 1 SBE 45 FTDI RS-232 cable DO sensor FTDI RS-485 cable Waveshare USB TO 2CH RS485 isolated · 120 ohm OFF CH1 tip · CH2 cmp YRDZXG 24 to 12 V the third one, potted in+in−out−out+ 1 2 3 4 5 6 7 8 9 +240V0V0V0V +12+12SDISDI TB1 · power and SDI-12 GNDDATA redblack TVS Baroblack Hygroblack Hygroclear Barored Hygrobrown Barowhite Hygrowhite BaroVUE blue and yellow (its RS-232 pair): cut short, taped, not used TB2 · wing cable 1 2 3 4 5 6 7 8 9 ABAB GGG HL orngor-whgrngr-wh brnbr-wh bluebl-wh Shield: trimmed back flush and sleeved, touching nothing (grounded at the wing box only) Tip meter on 1, 2. Compass on 3, 4. Trim actuator CAN on 8, 9. 1 2 3 4 5 1 · PG9 · 24 V in 16/2, its own 5 A breaker, branch bar B · Altelix 4-port split gland, on hand 2 BaroVUE 10 its own cable 3 HygroVUE 10 its own cable 4 SBE 45 line to wet lab box entry 14 5 DO sensor line to wet lab box entry 12
24 V, 12 V and 5 V power USB lead Wing RS-485 pairs Wing CAN pair Ground Sensor wires Cable passing through (coax, FTDI)

Wire list: every wire, from and to

TB = DIN TERMINAL STRIP · TOP = THE SIDE TOWARD THE HUB

Power and the two weather sensors (TB1)

WireFromTo
24 V redGland 1, the 16/2TB1-1 bottom
24 V blackGland 1, the 16/2TB1-2 bottom
Surge diode 1.5KE33CATB1-1, one legTB1-2, the other leg (no band to watch: it works either way round)
Converter in +YRDZXGTB1-1 top
Converter in −YRDZXGTB1-2 top
Converter out −YRDZXGTB1-3 top (its second black lead)
Converter out + (12 V)YRDZXGTB1-6 top
BaroVUE black (ground)Split gland B, port 2TB1-3 bottom
BaroVUE red (12 V)Split gland B, port 2TB1-6 bottom
BaroVUE white (SDI-12)Split gland B, port 2TB1-8 bottom
BaroVUE blue, yellowSplit gland B, port 2Cut short, taped (not used)
HygroVUE black (ground)Split gland B, port 3TB1-4 bottom
HygroVUE clear (shield)Split gland B, port 3TB1-5 bottom
HygroVUE brown (12 V)Split gland B, port 3TB1-7 bottom
HygroVUE white (SDI-12)Split gland B, port 3TB1-9 bottom
Adapter − (ground)SDI-12 adapter, one 3-pin SDI-12 terminalTB1-4 top
Adapter S (data)Same terminal; its + left emptyTB1-8 top
BridgesTB1-2 to 5 (all 0 V) · TB1-6 to 7 (12 V) · TB1-8 to 9 (SDI-12)

Hub power

WireFromTo
5 V redGland T, from Pi A (3 A fuse there)Hub terminal +
5 V blackGland T, from Pi AHub terminal −

The wing cable (TB2)

Cat6 wireTB2Then a short wire to
Orange1 bottomWaveshare CH1 A (tip meter)
Orange-white2 bottomWaveshare CH1 B
Green3 bottomWaveshare CH2 A (compass)
Green-white4 bottomWaveshare CH2 B
Brown5 bottomWaveshare PE next to A1, B1 (its channel 1 ground)
Brown-white6 bottomWaveshare PE next to A2, B2 (its channel 2 ground)
(none)7CAN adapter GND (its 5V0 terminal left empty)
Blue8 bottomCAN adapter CAN_H
Blue-white9 bottomCAN adapter CAN_L
ShieldTrimmed back flush, sleeved, touches nothing (grounded at the wing box only)
CableMike’s shielded Cat6 on hand, about 5 ft (Oct 21); strapped within a few inches of the box
EntrySplit gland S, port b, on the side wall, laid in from the side (port takes 0.15 to 0.30 in cable; the Cat6 on hand is 0.225 in, Mike, Oct 29)
BridgesTB2-5 to 7 (the ground for all three)

USB and coax: what plugs into what

ItemPlugs into
Hub’s own USB leadOut by S port a, to Pi A USB 1
CAN adapter’s USB leadHub port (Mike, Oct 20)
SBMS0 leadIn by S port c, into a hub port
Iridium A’s USB cableNot in this box: to its USB isolator on Pi A’s second USB port, in the Pi A box (Mike, Oct 20)
AIS antenna coax (PL-259)In by S port d, into the Superbat jumper; jumper’s BNC into the dAISy
dAISy (mini USB lead)Hub port
SDI-12 adapterHub port
Waveshare wing readerHub port
MOTU M2’s USB leadIn by S port e from the MOTU’s own box, into a hub port
SBE 45 FTDI cableHub port; its bare end out by split gland B port 4 to the wet lab box
DO sensor FTDI cableHub port; its bare end out by split gland B port 5 to the wet lab box
Two spare hub portsEmpty

Notes

Any device may take any hub port: each one is named by its serial number, not its port (System Settings Sheet sec 9). Every USB plug is tied down within 2 in and staked; at the hub, ties go round the hub body and across the plug grips. A ferrule on every stranded wire end. The wing Cat6 is likely solid 23 AWG: its wires go into the terminals bare, no ferrule, and the cable is strapped within a few inches of the box so the wires cannot flex there. Terminators: the CAN adapter’s 120 ohm switch ON, the Waveshare’s two OFF. Set the HygroVUE to address 1 (send 0A1! to it alone) before it joins the BaroVUE. No fuse in this box (Mike, Oct 14). One 1.5KE33CA surge diode across the 24 V input, legs short and sleeved (Mike, Oct 22). Wire colors for the two weather sensors are from Campbell’s manuals; read the labels on the cables to be sure. The MOTU M2 is in its own box (Mike); only its USB lead comes in here. Split gland S and gland T sit on a side wall: no holes on top of any box (Mike, Oct 31). Open: the box’s make and size (built; not logged); Mike’s word settles it.