Stern release wiring

Boat 1 · looking down, bow up · not to scale · no transom terminal box (Mike, Oct 27)Oct 27, 2026 · Updated 2026-11-01 · 1 page
TRANSOM (wires pass it only at the potted glands) PORT SIDE STARBOARD SIDE BOW ↑ CENTRAL NODE (Sheet A3) by the battery, forward · fuses, relays, MOSFETs and reverse relays all here 12 11 13 PG7 PG11 PG7 14/4 fire cable one piece, 0.40 in jacket opened here heat shrink over the cut end pair in a sleeve pair in a sleeve 18/4 port one piece, 0.25 in opened at the corner 1P 2P 18/4 starboard one piece, 0.25 in opened at the corner 1S 2S port quarter pullers: 1P drogue 1 · 2P drogue 2 starboard quarter pullers: 1S drogue 1 · 2S drogue 2 RELEASE NODE B Sheet A15 · horn B own cables, glands, route A B A B DROGUE BOX 1 outside, lid coils DROGUE BOX 2 outside, lid coils A = central node’s potted gland, B = Release Node B’s. Which box sits port or starboard: as built.
red +black −white or lightest +4th color − (green drawn)Release Node B, not these cables

Power

Release bus A (line 4, 30 A) and Release Node B’s feed (line 2, 30 A) come from the backup-fed bar on the main bus board. With the main side dead, the backup converter powers the pullers and both horns: one horn at a time (12.5 A each, under a second), steering paused for the burn.

The three cables

GlandCableWires
11, PG1114/4 tinned (CONEPY), 0.40 in, one piecered + / black −: drogue box 1 lid coils. White + / 4th −: drogue box 2 lid coils. 14 AWG, 12.5 A while firing
12, PG718/4 shielded tinned, 0.25 in, one piece, to the port quarterred + / black −: puller 1P. White + / 4th −: puller 2P
13, PG718/4 shielded tinned, 0.25 in, one piece, to the starboard quarterred + / black −: puller 1S. White + / 4th −: puller 2S

Fire pairs: + is the release bus, − goes to that channel’s MOSFET module. Puller pairs: both wires leave the puller’s reversing relay. Write in the real 4th colors at first cut: 14/4 ______ · 18/4 ______.

At the far ends

  • 14/4: open the jacket inside the hull near the drogue boxes’ potted glands. Glue-lined heat shrink over the cut jacket end. Each pair on in a sleeve to its own gland A, then crimped to the lid coil tails (Drogue Box Guide sec 5). No joint anywhere.
  • 18/4s: open the jacket at the quarter, heat shrink over the cut end, each pair to its puller motor, crimped. Wire it so the pulley winds the line in (Drogue Box Guide sec 6).
  • Shield drains: to the 24 V negative at the central node only. At the corners, trim the drain and foil back and sleeve them.

Rules

  • Feed dead before any wire is handled: main battery switch and backup converter off, or lift the feeder’s lug at its 30 A breaker. No breaker has an off lever.
  • Labels at both ends of every wire: D1+, D1−, D2+, D2−, 1P+ … 2S−.
  • Ferrules on ends under screws; crimps, never solder.
  • One cable per gland. These three never share a gland, bundle or route with Release Node B’s runs.
  • Chafe sleeve wherever a cable crosses a hard edge; drip loop at each gland.

Cable on hand

  • 14/4: 30 ft roll, bought Sept 27. One run of about 10 to 12 ft plus the two pairs leaves plenty.
  • 18/4: 50 ft roll (C4), also feeds the wing actuator run and the short bilge cable. Two runs to the quarters: measure what is left after the wing run before cutting.

Gone with the box

  • The transom terminal box, its 12-terminal strip and its 7 glands; no 14/4 tail pieces, no 18/4 splices. The 9.5 x 5.5 in box is free for another job.

Homes: Electronics and Wiring Plan A3 entries 11, 12 and 13; Box Wiring Sheets A3 and R1; Transom Drogue Box Guide secs 5 and 6.