Boat 1 · looking down, bow up · not to scale · no transom terminal box (Mike, Oct 27)Oct 27, 2026 · Updated 2026-11-01 · 1 page
red +black −white or lightest +4th color − (green drawn)Release Node B, not these cables
Power
Release bus A (line 4, 30 A) and Release Node B’s feed (line 2, 30 A) come from the backup-fed bar on the main bus board. With the main side dead, the backup converter powers the pullers and both horns: one horn at a time (12.5 A each, under a second), steering paused for the burn.
The three cables
Gland
Cable
Wires
11, PG11
14/4 tinned (CONEPY), 0.40 in, one piece
red + / black −: drogue box 1 lid coils. White + / 4th −: drogue box 2 lid coils. 14 AWG, 12.5 A while firing
12, PG7
18/4 shielded tinned, 0.25 in, one piece, to the port quarter
red + / black −: puller 1P. White + / 4th −: puller 2P
13, PG7
18/4 shielded tinned, 0.25 in, one piece, to the starboard quarter
red + / black −: puller 1S. White + / 4th −: puller 2S
Fire pairs: + is the release bus, − goes to that channel’s MOSFET module. Puller pairs: both wires leave the puller’s reversing relay. Write in the real 4th colors at first cut: 14/4 ______ · 18/4 ______.
At the far ends
14/4: open the jacket inside the hull near the drogue boxes’ potted glands. Glue-lined heat shrink over the cut jacket end. Each pair on in a sleeve to its own gland A, then crimped to the lid coil tails (Drogue Box Guide sec 5). No joint anywhere.
18/4s: open the jacket at the quarter, heat shrink over the cut end, each pair to its puller motor, crimped. Wire it so the pulley winds the line in (Drogue Box Guide sec 6).
Shield drains: to the 24 V negative at the central node only. At the corners, trim the drain and foil back and sleeve them.
Rules
Feed dead before any wire is handled: main battery switch and backup converter off, or lift the feeder’s lug at its 30 A breaker. No breaker has an off lever.
Labels at both ends of every wire: D1+, D1−, D2+, D2−, 1P+ … 2S−.
Ferrules on ends under screws; crimps, never solder.
One cable per gland. These three never share a gland, bundle or route with Release Node B’s runs.
Chafe sleeve wherever a cable crosses a hard edge; drip loop at each gland.
Cable on hand
14/4: 30 ft roll, bought Sept 27. One run of about 10 to 12 ft plus the two pairs leaves plenty.
18/4: 50 ft roll (C4), also feeds the wing actuator run and the short bilge cable. Two runs to the quarters: measure what is left after the wing run before cutting.
Gone with the box
The transom terminal box, its 12-terminal strip and its 7 glands; no 14/4 tail pieces, no 18/4 splices. The 9.5 x 5.5 in box is free for another job.
Homes: Electronics and Wiring Plan A3 entries 11, 12 and 13; Box Wiring Sheets A3 and R1; Transom Drogue Box Guide secs 5 and 6.