Boat 1 · both pumps · a wiring map, not to scale, not placed as on the boatOct 31, 2026 · Updated 2026-11-01 · 1 page
+24 V (pump 2: backup battery)0 Vswitch out (on when wet)manual-onunused corepump running signalcablejoint
How it works
Water runs the pump, no computer needed. Pump 1: line 11’s 5 A breaker, then Water Witch 1 (turns on when wet 6 to 8 s; runs 15 s more when dry). Pump 2: the backup battery, always: line 15’s 5 A breaker, a BatteryProtect, then the Ultima switch, sealed so the bilge water cannot join the two sides.
Two steps by height. The Ultima sits higher: pump 2 starts only if pump 1 falls behind.
Pump 2 cannot flatten the backup battery. The BatteryProtect cuts it at about 30% left; its remote input goes to Pi B, so shore can stop a stuck pump 2.
Shore can run either pump. Ch 6 puts 24 V on pump 1’s +, after the Water Witch, no diode; pump 2’s manual-on is on Pi B’s side. A dead node leaves ch 6 open.
Run signals. Pump 1’s + to opto input 1. WD-B watches pump 2’s running line and wakes Pi B at once; Pi B runs pump 2’s monthly 5-second exercise.
Power-up: Water Witch 1 runs pump 1 a few seconds to set itself. Not a leak.
The runs
Run
Wire
Water Witch 1
From the maker: three 16 AWG, 30 in. Red to J3, black to J2, tan to J1. Rated 15 A at 24 V
Ultima
Johnson 36303, 10 A at 24 V. Feed to J3, 0 V to J2, pump lead to J1 (colors per Johnson’s sheet)
Pump feed
Pump 1: 16/2, good to 22 ft. Pump 2: 14/2 (roll on hand). Red to J3, black to J2
Bilge cable
C4 18/4 shielded, one piece from node entry 9. Red: P1 ON, after ch 6’s 5 A fuse. Black: P1 RUN, opto input 1. White, 4th: unused, sleeved (ch 12, opto input 2 spare). Shield sleeved both ends
At the pumps
Each pump’s ON and RUN wires join its + at J1, after its switch, no diode (pump 2’s from Pi B’s side)
Rules
Every joint above the highest bilge water, sealed. Crimped, never soldered.
Service loops so a pump comes out without cutting anything.
Dead first (no breaker has an off lever): pump 1, main battery switch off; pump 2, lift one end of the backup board’s 30 A ANL.
P1 RUN and P2 RUN carry 24 V while their pump runs: colored heat shrink and labels at both ends, never on a 0 V terminal.
Label both ends: P1+, P1−, P1 ON, P1 RUN; same for P2.
Still open
The part for J1 and J2 (three wires each) is not set.
Where pump 2’s two signal wires enter on Pi B’s side, and which relay module switches its manual-on. The BatteryProtect’s exact cut voltage.
Homes: Build Guide sec 3.6; Electronics and Wiring Plan secs 4.1, 7.6, A3 (entry 9) and A10; Compute Bay Plan sec 11; Backup Battery Board Layout; Water Witch 217/230/230-24 install sheet.