Surge clamps at the actuator, inside the pocket  Nov 2, 2026 · not to scale

Thomson actuatorits four wires 24 V +24 V −CAN HCAN L DTMplug cable down the PEX one clamp on each wire: 33 V33 V12 V12 V 1.5KE33CA (on hand)1.5KE12CA (to buy) 120 ohm resistor, CAN H to CAN L WAGO 221-415 lever connector 12 AWG tail, 6 in landing screw 2(the ground wire's) Red: the four pigtails, 4 in each, spliced in beside the plug. Each clamp and the resistor in heat shrink; the bundle tied to the motor shelf.

What it does

A surge clamp does nothing until the voltage across it passes its number, then dumps the surge to ground and goes back to doing nothing. One on each of the actuator's four wires: 33 V on the two power wires, 12 V on the two data (CAN) wires. "CA" means either leg can go either way.

Build

  1. Strip each of the 4 wires about 3 in from the plug. Butt-splice on a 4 in pigtail.
  2. Crimp a clamp leg on each pigtail: 33 V on power, 12 V on CAN. Heat shrink.
  3. The 4 other legs and the 12 AWG tail go into one WAGO 221-415.
  4. 120 ohm resistor across CAN H and CAN L, heat shrink. (Skip it if Thomson's manual says the MD has one inside.)
  5. Tail: yellow #10 ring on landing screw 2, with the ground wire.

Parts

  • 2 x 1.5KE33CA: on hand. 2 x 1.5KE12CA: Amazon B00LQQ47BK (Littelfuse 5-pack). 1 x 120 ohm 1/4 W resistor. 1 x WAGO 221-415. Butt splices and heat shrink on hand.