Box Wiring Sheets

One drawing per box: what lives inside it, how the pieces wire to each other, and every cable through the wall. Companion to the Electronics and Wiring Plan; entry numbers and gland sizes match Appendix A hole for hole. Every decision in the v10.2 guides is drawn in, the slip ring through the wing’s turning joint among them.

BoatNobotic USV, Cape Dory 25D
Revisionv10.2 basis · drawn 2026-08-23, rev 2026-10-09
SourceElectronics and Wiring Plan, App. A
Sheets20 (overview, A1 to A16 with A6a, release map)

How to read a sheet. The heavy outline is the box wall. Blocks inside are the boards and parts that live in the box; colored lines are the wires between them. Numbered circles on the wall are the cable entries, numbered exactly as in Appendix A of the wiring plan, with the gland size under each and where the cable goes just below. Every entry is a nylon IP68 gland unless it is marked as an RJ45 coupler or an SMA bulkhead, and only cables that leave the cabin get a mix-31 ferrite, on the outside (Electronics and Wiring Plan sec 7.5). Entry positions on these sheets are drawn for readability; the real holes go where the drilling templates put them.

Printing. US letter, landscape. Each sheet prints as its drawing on one page and its notes on the next; the simplest boxes (A5, A10 to A13) fit drawing and notes on one page.

Wire classes

DC power (24 V feeds, battery, 5 V rails)
CAN, control bus
CAN, house bus
Release channels

 

Serial data (USB, UART, I2C, 1-wire)
Ethernet
Coax / RF
Field sensors and contacts

Wall symbols

1 Gland, numbered per Appendix A
RJ45 coupler (square) / SMA noted in text
V Gore vent · B bond stud
Lightning ground (boxes wired to the lightning copper only)
SheetBoxHoles
0The whole network, box to box 
A1Pi A box (aluminum, main island, lightning stud)10 + V + B (S and 7 share one split gland; 12, S, 7 to the hub box)
A1aUSB hub box (beside Pi A; the hub, science adapters, dAISy and wing readers; box not picked)6 + one 5-port split gland (+ V if plastic)
A2Pi B box (aluminum, backup island, floats)8 + V
A3Central node (release, two relay modules, the charging stop, the Ewellix steering drive)15 + 2a + V (one more if entry 15 is needed)
A4BMS box as bought, on the battery box’s aft wall (watchman; monitoring only)4 + V
A5FSESC box: deleted, neither boatnone
A6Aft junction (plastic, passive, stern; nav lights arrive switched, no photocell; no network parts)~14 + V (measure the box)
A6aNetwork switch box (aluminum, beside the aft junction, glued to the hull; the TSW202 switch and its supply only, on a DIN rail), with the network surge board near the deck (the five Ethernet surge protectors, not a box)10 + V
A7VESC A box (main propulsion)8
A8VESC B box: Boat 2 only, not fitted on Boat 17 (Boat 2)
A9Battery box (main bank)3 + V + relief stub + fuse, BMS box bolts
A10Emergency bank: a bought Dyness battery, no box to buildnone
A11-AIridium A box (main island)3 + V
A11-BIridium B box (emergency island)3 + V
A12Detector mini-box (AS3935)1 + V
A13Starlink enclosure (deck)2 + deck stub
A14Native devices, no drilling; the wing through its slip ring into the new wing box below the deck, where the wing's wires enter the hulltee + drop; wing box: at least 3
A15Release Node B (second release chain, stern)4 + V
A16Transom terminal box (passive fan-out; entry 10 plugged)6 + 1 plugged + V
R1Release path map: which node releases whatno box

Sheet 0 · The whole network · v10.2

CONTROL BUS · 12 V ON THE PAIR · FED ONCE: 5 A BREAKER AT THE MAIN BUS BOARD, 24 TO 12 V CONVERTER AT THE COMPUTE MULTIPORT 120 Ω END 120 Ω END power tee VESC A Electrak (Boat 2) 120 Ω END 120 Ω END power tee em-trak VESC B (Boat 2) Release Node B 4-port PI A BOXmain island · lightning stud PI B BOXbackup island · floats CENTRAL NODErelease + monitoring AFT JCTpassive USB HUBscience,AIS, wing WING slip ring, eight wires WING BOX below the deck wing cable Ethernet: separate Cat6 runs to the TSW202 at the aft junction Pi B: plain UTP alive(opto) IRIDIUM Amain bank STARLINKCat6 to SFP 9 BMS BOXwatchman, no charger wires USB to hub EMERGENCY ISLAND · own bank, no copper path IRIDIUM Bemergency bank DETECTORAS3935, <3 ft EMERG. BANKDyness 24V 100Ah, bought ORION-TRonly power bridgerelay ch 10 from main bus board 7-core to WD-B TSW202 switch, aft junction 8 PoE + 2 SFP, always on fwd post 1 • aft post 2 foredeck fisheye 3 interior 4 • underwater 5 light driver 6 • Pi A 7 Pi B 8 • SFP 9 Starlink RELEASE NODE Bsecond release chain TRANSOM BOXpassive fan-out HOUSE BUS · 12 V ON THE PAIR, FED THE SAME WAY FROM ITS OWN BREAKER AND CONVERTER
Sheet 0 · The whole network · notes
CONTROL BUSHOUSE BUSEMERGENCY ISLAND

What it shows. Two CAN rails, one Ethernet star, and one floating island. Steering and release channels ride the control bus; the busier monitoring traffic rides the house bus. Only the Pis touch both rails. Boat 1 steers with one actuator; there is no FSESC box.

Bus power. Each bus carries 12 V on its power pair, fed once from its own 5 A breaker at the main bus board and its own 24 to 12 V converter at the compute multiport.

Emergency island. Pi B, Iridium B and the lightning detector run on the emergency bank with no copper path to the main system. Every one of their data links crosses on an isolator, a transformer, or plain UTP (unshielded network cable), whose bulkhead jack’s metal touches no wire or shield. The one power bridge is the Orion-Tr, a charger isolated by its own transformer, which central node relay channel 10 runs 90 minutes a day.

Bus order as built. Control: power tee, 4-port multiport (Pi A, Pi B), VESC A, central node. The Electrak tee is Boat 2 only and unwired; Boat 1 steers with the Ewellix CAHB-22, a plain DC actuator driven from the central node, not a bus device. House: power tee, multiport, em-trak, VESC B (Boat 2 only; its tee is unwired on Boat 1), and Release Node B as the bus end. The aft junction is on no bus: nothing in it talks on CAN. The terminators (the 120 ohm end resistors) sit on the spare port of the end tees; HAT termination jumpers off.

Also shown. Release Node B (Sheet A15) at the stern, with the passive transom terminal box (Sheet A16) beside it, on no bus. The USB hub box beside Pi A (A1a), the Orion-Tr (A10), and the wing on its slip ring, no radio, into the wing box below the deck (A14). The wing box sends one shielded 4-pair cable to the hub box, where Pi A reads the tip wind meter and the wing compass and talks to the trim actuator on the actuator’s own CAN link, kept off both buses.

A1 · Pi A box · v10.2

5.1 V to the carrier to hub 24 V coil MEAN WELL DDR-60L-55 V 12 A, isolatedDIN rail, set to 5.1 Vnegatives tied WD-A RELAYNC contact, 24 V feed 24 V TERMINAL STRIPno fuse block: breaker at bar TVS + INA226feed monitor 3 A FUSEhub 5 V heartbeat 15k safe-mode wire, pin 37 22k from pin 37 to ground WD-ANano Everyown 5 V: Pololu D36V6F5 alive kill UART PC817 OPTO BOARD CM5 ON CARRIER boots from eMMC (its safe copy too) · clock capped about 2.0 GHz 2-CH CAN FD HAT, isolated USB 1: hub lead (entry S) · USB 2: wing CAN adapter (entry 7) 4 TB NVMe + Hailo-8L, the two M.2 slots control drop house drop ADuM hub lead CAN adapter CM5 Ethernet drain IMU A1BNO085, I2C HUMIDITYbreakout, I2C IMU A22nd I2C address GPS UART GPS ANEO-7M (bought) 1 12 V 6 4 2 B 3 5 S 7 8 11 PG9main 24 Vfeed10 A breaker 1/2 inGore vent PG7alive linkto Pi Bopto inside PG7VESC AUART + killcut cable PG7CANcontrolfrom tee 1/4 inbond stud1/4-20to the copper PG7CANhousefrom tee PG7Iridium Aserialcut cable RJ45to TSW202port 7jack, taped SMAGPS Aantennano arrestor 12 · PG7hub 5 V lead3 A fuse in Pi A S + 7 · one split glandAltelix PG25 4-port, 2 ports pluggedhub lead (USB 1), CAN adapter (USB 2) Not drilled: 9 and 10 (Pi B and Starlink run to the TSW202), 13 (no wing radio) and 14 (no RTL-SDR). all three go to the USB hub box beside Pi A: Sheet A1a
A1 · Pi A box · notes
ALUMINUM · CXCESNSMAIN ISLANDBOTH BUSESLIGHTNING STUD + HULL-COOLED

What it is. The main brain. Glued to the hull below the waterline for cooling, at least 2 ft from the main battery and motor cables where space allows, for the IMUs (a guess at a safe distance); bond stud wired to the lightning copper. Entries go on any face but the glued back face, with drip loops (drawn on the bottom). Every line from off the island crosses an isolator or an optocoupler before it touches the CM5.

Power. The 10 A breaker at the bar (entry 1), then inside: the TVS, the INA226, the terminal strip, WD-A’s relay and the Mean Well DDR-60L-5 converter (5 V 12 A, 18 to 75 V in, isolated, on a short DIN rail at the far end of the plate from the IMUs; output set to 5.1 V, output negative tied to input negative), then the carrier. The relay is a 5 V 1-channel module with Pi A’s 24 V feed through its normally closed contact, ahead of the converter: coil off means Pi A on, so a dead Nano leaves Pi A running. WD-A cycles Pi A after five minutes of heartbeat silence. WD-A runs on its own Pololu D36V6F5, fed ahead of the relay, so the relay never cuts it. The hub’s 5 V lead takes off the converter’s output on a 3 A inline fuse and leaves by entry 12, so the hub restarts whenever WD-A cycles Pi A.

Entries. Eleven, plus the vent and the bond stud: 1 to 8, 11, 12 and S. Not drilled: 9 and 10 (Pi B and Starlink run to the TSW202), 13 (no wing radio) and 14 (no RTL-SDR). One mix-31 ferrite, on the GPS A coax only. The CAN shield drain lands on the bond stud here and nowhere else. Entry S carries the hub’s USB lead to Pi A’s first USB port, with no USB isolator; entry 7 the wing CAN adapter’s own lead to the second; S and 7 share one Altelix PG25 4-port split gland (on hand; two ports plugged), so both USB plugs pass without cutting (Pending 423); the adapter’s lead goes never a hub port, so the wing’s control never depends on the hub. The kill line (entry 4, beside the VESC UART) and the alive line to Pi B (entry 6) leave WD-A through a HiLetgo PC817 optocoupler board. The Ethernet bulkhead jack’s outside face is greased and taped (Sheet A6a).

Inside. Two IMUs, A1 and A2 (BNO085), on the same I2C pair, A2 at the chip’s second address, one at each end of the plate, far from the converter, each with a forward arrow on the plate. The safe-mode wire runs from a WD-A output pin to header pin 37, the 15k in the wire and the 22k from pin 37 to ground, so the pin sees about 3 V, not 5 V; no box hole. Pi A’s motor kill pin, when assigned, must not use pin 37. Vent, desiccant, humidity breakout; boards conformal-coated. The 4 TB NVMe and the Hailo-8L go in the carrier’s two M.2 slots; bench-prove both. GPS A is a NEO-7M, position only. USB cables clamped within 2 in of their plugs, plug bodies staked. FTDI chips only, never CH340.

USB hub box. Now on its own sheet, A1a: the hub, the science adapters, the dAISy and the wing’s two readers. Three leads link it to Pi A: the hub’s 5 V lead (entry 12), the hub’s USB lead (entry S) and the CAN adapter’s lead (entry 7).

A1a · USB hub box · v10.2

TOP WALL: ONE SPLIT GLAND, ALTELIX PG25 5-PORT (ON HAND) c SBMS0 USB lead in, from the BMS box (Sheet A4, entry 4) e MOTU M2 lead, if the MOTU sits outside; else the port is plugged a hub’s USB lead out, to Pi A USB 1 (Pi A entry S) d AIS antenna coax in: the Eifagur’s RG-58, PL-259 plug on b CAN adapter’s lead out, to Pi A USB 2 (Pi A entry 7) Plugs pass through; the slit seal closes round each cable. Nothing is cut. PG7hub 5 V lead infrom Pi A entry 12, 3 A fuse there 5 V STARTECH USB210AIND · 10-PORT USB 2.0 HUB DIN rail · 5 V on its terminal block · detachable USB lead · three ports spare c e a d b DSD TECH SH-C30G USB to CAN, isolated120 ohm switch ON Superbat jumper, 1 ftSO-239 in, BNC out SDI-12USB adapterBaro + Hygro SBE 45FTDI RS-2320 V version DO SENSORFTDI RS-485chip in the plug WAVESHARE 2-CHRS-485, isolatedtip meter + compass dAISy 2+BNC antenna socketmini USB · always on 24 V, no fuse 24 TO 12 V3rd YRDZXG 12 V TERMINAL BLOCKwing cable pairs + brown ground orange + green blue pairCAN brown: each adapter’s ground Not fitted: DROK 24 to 5 V converter, USB isolator, relay for the hub alone. 24 V in16/2, own 5 A breakerfor the 12 V only SDI-12 + 12 Vto BaroVUE 10and HygroVUE 10 SBE 45 lineRS-232, barewire end DO sensorto the wet labbare wire end wing cable inshielded Cat6, 4 pairs, plugs cut offshield trimmed back here (Sheet A14) Dashed: gland size picked at fit-out, once the box is bought.
A1a · USB hub box · notes
BOX NOT PICKED YETMAIN ISLANDNO BUS · TWO USB LEADS TO PI ABESIDE PI A

What it is. A small box of its own beside Pi A (Electronics plan A1a), because Pi A’s box is full. It holds the USB hub and everything that plugs into it, plus the wing’s two readers. It is on no bus: its only links to the computer are two USB leads to Pi A.

Power. Two feeds. The hub runs off Pi A’s 5 V: a short 2-core lead from Pi A’s Mean Well, on a 3 A fuse inside the Pi A box, out by Pi A entry 12 and in by this box’s top PG7 gland, so the hub restarts whenever WD-A cycles Pi A. The box’s own 24 V feed (16/2 on its own 5 A breaker at the branch bar) feeds only the third YRDZXG 24 to 12 V converter, with no fuse on either side of it: the 5 A breaker is the only protection (Mike, 2026-10-14, Pending 426); the 12 V goes out with the SDI-12 line to the BaroVUE 10 and HygroVUE 10, never the 24 V bus.

The hub. StarTech USB210AIND, 10 ports, DIN rail, 5 to 24 V in on a terminal block. Its ports: the SDI-12 adapter, the SBE 45’s FTDI USB-RS232-WE-1800-BT-0.0 cable (RS-232, Mike 2026-10-14; the 0 V version, no power out on its wires), the DO sensor’s FTDI cable, the Waveshare wing reader, the dAISy, the SBMS0 lead and the MOTU M2; three spare. Its own USB lead is detachable: clamp and stake it at both ends.

Leads that keep their plugs (Pending 423, Mike 2026-10-14) go through one Altelix PG25 5-port split gland in the top wall: the hub’s lead and the CAN adapter’s lead to Pi A, the SBMS0 lead from the BMS box, the AIS antenna coax with its PL-259 on, and the MOTU M2 lead if the MOTU sits outside (else that port takes its plug). The cable lays into a slit seal from the side, so no USB plug is ever cut off. Lines with a bare wire end (the DO sensor, the SBE 45, SDI-12, the wing cable, the 24 V feed) go through ordinary glands in the bottom wall, the wire end fed in from inside.

AIS. The dAISy 2+ has a BNC antenna socket and a mini USB port (Pending 422). The Eifagur stubby VHF antenna’s 16 ft of RG-58 ends in a PL-259; it screws into a Superbat 1 ft SO-239 to BNC jumper, whose BNC end plugs into the dAISy. A flexible jumper, not a solid adapter, so the coax’s weight never levers on the dAISy’s socket. No SMA bulkhead and no SMA to SO-239 jumper. AIS from the dAISy depends on the hub; the em-trak is the second receiver.

The wing. The wing cable from the wing box (Sheet A14) is any shielded Cat6, all copper, plugs cut off. It lands on a terminal block: blue the trim actuator’s CAN pair, to the DSD TECH SH-C30G (120 ohm switch on); orange the tip meter’s RS-485 and green the compass’s, to the two channels of the Waveshare USB TO 2CH RS485 reader (terminators off); brown the ground, tied to the wing’s 24 V negative in the wing box and here landed on each adapter’s ground terminal. The shield is grounded at the wing box only: here it is trimmed back and sleeved, touching nothing. Both readers are isolated, so a strike on the wing stops at them. The CAN adapter’s lead goes straight to Pi A’s second USB port, never a hub port, so the wing’s control never depends on the hub.

Rules. FTDI chips only for serial, never CH340. Every USB plug clamped within 2 in and staked. No USB isolator (one 5 V supply: it would isolate nothing). Not fitted: the DROK 24 to 5 V converter bought for the hub, and a relay to cycle the hub alone. If the hub drops off, Pi A tries a USB reset, then stops its heartbeat so WD-A cycles Pi A and the hub together.

Open: the box itself (its material, and so whether it takes a vent) and each bottom gland’s size; buying the box settles them. Open: which bus bar stud feeds it, the end stud or stud 8. Open: where the MOTU M2 sits.

A2 · Pi B box · v10.2

5 V 24 V coil 24 V TO 5 VKlnuoxj, pottedTVS, floating − WD-B RELAYNC, 24 V feed FUSE + STRIPemergency 24 V 7-core,under 3 ft alive WD-BNano Everyown 5 V: D36V6F5owns lightning role LEVELSHIFTER PC817opto CM5 ON CARRIER the island copy of the brain CAN FD HAT, isolated (the bus isolation) control house ADuM iso built-inmagnetics 256 GB NVMemirrored state IMU BBNO085, I2C GPS BNEO-7M (bought) HUMIDITYI2C breakout DESICCANTin the box No bond stud. Plastic glands only. Ethernet jack: the Alrhso, on UTP. No metal shell or shield ties it to Pi A. 1 6 5 2 3 4 8 9 V 7 PG7emergencyfeedown bank PG7AS3935detectorto WD-B PG7alivediscrete, Pi Aopto inside PG7CANcontrolfrom tee PG7CANhousefrom tee PG7Iridium Bserialcut cable RJ45Ethernetto TSW202UTP, Alrhso SMAGPS Bantennano arrestor 1/2 inGore vent blanknot used
A2 · Pi B box · notes
ALUMINUM · CXCESNSEMERGENCY ISLANDBOTH BUSES, ISOLATEDFLOATS · NO BOND STUD

What it is. The backup brain, a few feet from Pi A on the settee panel, electrically nowhere near it. Power comes from the emergency bank only, through a fuse, a terminal strip, WD-B’s relay and its own potted Klnuoxj 24 to 5 V converter with TVS, the negative left floating (tied to nothing). The relay is a 5 V 1-channel module with Pi B’s 24 V feed through its normally closed contact, ahead of the converter: coil off means Pi B on, so a dead Nano leaves Pi B running. WD-B runs on its own Pololu D36V6F5, fed ahead of the relay, so the relay never cuts it. Every data link crosses on something that does not conduct: the CAN HAT’s isolation, the Ethernet jack’s transformer, an ADuM isolator chip on the Iridium B serial line, and a HiLetgo PC817 optocoupler board on the alive signal from Pi A. WD-B owns the whole lightning role and reads the AS3935 detector on a short 7-core lead, through a 4-channel two-way level shifter inside this box (the detector works at 3.3 V, the Nano at 5 V). WD-B never cuts Pi B’s power for lightning.

The five isolation rules, drawn. 1) Emergency-bank power only. 2) Every data link optical or transformer coupled. 3) No metal shell or shield ties this box to Pi A: plastic glands, plain UTP (unshielded network cable), so the Alrhso bulkhead jack’s zinc and plastic body touches no wire or shield; its outside face greased and taped (Sheet A6a). 4) No bond stud. 5) Everything else on the emergency bank (Iridium B, detector, WD-B) lives on this side. Entry 7 stays blank.

A3 · Central node · v10.2

Vmembrane vent, wall DIN RAIL, SCREW TERMINAL BLOCKS: EVERY FIELD WIRE LANDS HERE FIRST NUCLEO-G431KBNano screw carriermap on the lid CAN TRANSCEIVER+ DIN surge module MCP23017I2C expanderall 16 used BME280 + HUMIDITYI2C breakouts 24 V TO 5 VKlnuoxj, potted+ 1.5KE33CA in NODE FEED15 A breaker release feeder 12/2, 30 A breaker at bar Nucleo sensor lines: I2C (humidity · BME280 · MCP23017) · 1-wire ×2 · encoder A PWM · wind UART (Calypso CMI1018) native Nucleo pins (21 of 22): ch 5 coil · ch 13 horn · release gates · Ewellix PWM, DIR, current, wiper MCP23017: coils of ch 1 to 4, 6 to 12, the steering cut; 4 inputs (opto, G2 fault) RELAY MODULE 1 · 8-CH 24 V · ALL 8 USED 1 StarlinkNO 2 wet labNO 3 nav ltsNC 4 em-trakNC 5 ENABLENO · pin 6 bilgeNO 7 whitesNO 8 CHARGENC six 16/2 runs aft release bus MOSFET MODULESrelease ch 1 to 6 CHARGER RUNjoined at bus board batt +via 1k one run tobus board batt + in EWELLIX DRIVE + CUTPololu G2 24v13+ 30 A cut relay OPTO BOARD ×1Water Witchstates ×2 RELAY MODULE 2 · ON THE EXPANDER 9 UV-CNC 10 OrionNO 11 reverse(test) NO 12 bilge 2, NO13 horn, pin A2 REVERSING RELAYS ×4 24 V DPDT, 10 A coils: ch 11 reverse fuse + 1N5408, input side ch 9: camera port UV-C ch 10: Orion-Tr, 90 min a day ch 11: puller reverse, test only Neither Pi heard for the set time: the node drops ch 8, so charging resumes, and turns on ch 3, the nav lights, until a Pi is back. At the main bus board, not here + bar 1k 1 W thin wire, entry 22 Ahead of the branch breakers, heat-shrunk, own terminal. Limits the whole run to about 29 mA: no fuse. 2 1 12 13 16 2a 3,4 22 27 28 29 30 18 25 17 20 14,15 PG924 V feedmain bank PG7CAN controlfrom teebus END PG11Ewellixfeed in14/2, 20 A PG11Ewellixmotor + fbto actuator PG13.5 ×2switchedloads out6× 16/2 entry 2areleasefeeder 12/2PG11 or PG13.5? PG11 ×2release trunksto transom boxpower only PG9 · filledcharger run out,batt + instrip at bus board PG7camera portUV-C, ch 9to the LM317 PG7Orion-Tron/off, ch 10to its remote wet lab line into relay ch 2PG9 battery and air1-wire ×2PG9 · filled sparenot drilled spareno I2C shuntsnot drilled spareno surge statusnot drilled hornch 13PG9 sensors, 15 if neededaft trunksPG11 ×2
A3 · Central node · notes
PLASTIC · ~16 × 12 × 6 INCONTROL BUSNEAR BATTERY / BUSBARS / COMPUTERELEASE · LOADS · CHARGING STOP

What it is. The one team-built node: a Nucleo, screw-terminal boards and a DIN rail where every field wire lands first. It fires the releases, switches the loads, holds the charging stop, drives the Ewellix and reads the sensors. Print the relay map (Compute Bay Plan sec 11, table below) on the lid.

Reading the drawing. Red: relay channel 5, the release enable relay. Amber: channel 8 (charging) and channels 9 and 10. Dashed blue: logic lines. Dashed circle: the release feeder, entry 2a. Entry 29 (top) brings the wet lab’s own 16/2 line in from its 15 A breaker to channel 2; it leaves on one of the six runs aft. Entry 30 (top right) takes the horn’s 16/2 pair from relay channel 13, through its 5 A inline fuse, to the horn low on the instrument post. The charging stop’s 1k resistor sits at the main bus board (dashed box). Not drilled: 17, 20, 21 and 23 to 26 (17, 20 and 25 are spares, drilled only when a cable needs one); entry 15 only if the count needs it.

Relay chWhat it switchesContactCoil driven from
1Starlink powerNormally openExpander
2Science payload group: the wet lab’s own 15 A line, in by entry 29Normally openExpander
3Nav lights (bow lantern, stern light), sunset to sunrise, and by day too in fog modeNormally closed: a dead node leaves the boat litExpander
4em-trak AIS transponderNormally closed: fails ONExpander
5Release enable relay: feeds the release busNormally open: dead, the bus is deadNative Nucleo pin
6Bilge pump 1 manual-onNormally openExpander
7Motoring whites (coil of the aft junction’s 30 A relay): on only when dark and the motor runs; in fog mode, whenever the motor runsNormally openExpander
8Charging relay: coil on stops all five chargersNormally closed: dead, the chargers runExpander
9Camera port UV-C, 5 min on and 10 off, in softwareNormally closed: a dead node leaves the UV onExpander (module 2)
10Orion-Tr on/off: 90 minutes a day, and the monthly rechargeNormally open: a dead node leaves it offExpander (module 2)
11Cord puller reverse (test): coils of the four reversing relaysNormally open: dead, the pullers run forward onlyExpander (module 2)
12Bilge pump 2 manual-on, and its monthly 5-second dry runNormally openExpander (module 2)
13Horn: its 24 V through a 5 A inline fuse, out by entry 30 to the post; shore command, and one long blast every 2 minutes in fog modeNormally open: a dead node leaves it silentNucleo pin A2 (native)
14 to 16Not used as relays. The expander pins of 13 to 16 read the Water Witch states, the release bus readback and the G2 faultnoneExpander inputs

Steering and sensors. The Ewellix CAHB-22 runs from a Pololu G2 24v13 motor driver (on hand since 2026-09-28), behind a 30 A power-cut relay that is closed when unpowered. Feed in by entry 12, 14/2 on its own 20 A breaker (Electronics plan 7.6); motor and feedback out by 13. Encoder A, wind and the Water Witch states arrive on the aft trunk. Chain 1 carries the battery trip. The opto board’s outputs (Water Witch states, release bus readback) and the G2 fault line go to the expander, on the pins that were relay channels 13 to 16. Not fitted: short relays, branch current meters, a VE.Direct reader, gas sensors.

Nucleo pinJobNucleo pinJob
D0, D1Wind meter in, out (Calypso CMI1018)D3Relay ch 5 coil (release enable)
D2, D10CAN board TX, RXD7, D8Release gates ch 1, 2
D4, D5I2C data, clock (expander, BME280, humidity)A3, A6Release gates ch 3, 4
D6Encoder AA4, A5Release gates ch 5, 6 (after the links come off)
D9, D13Steering PWM, DIR to the G2D11, D121-wire chain 1 (battery trip), chain 2 (air)
A0, A1G2 current sense, Ewellix wiperA2, A7A2: relay ch 13 coil, the horn. A7: spare

Before burn-in, take off the four solder links that join A4 to D4, A5 to D5, and A2 and A7 to the USB serial (check the link numbers in the board manual). The G2 needs its terminal blocks soldered on at the bench too.

The charging stop, beside relay 8. Battery positive comes in by entry 22 on its own thin wire from the main bus board’s positive bar, ahead of the branch breakers, through the 1k 1 W resistor at the bar. Never take it off the node’s own feed: a tripped node breaker would then stop all charging. It runs through channel 8’s normally closed contact and back out by entry 22 on one run to the main bus board, where the yellow wires of the five Victron remote on/off cables (ASS030550320) meet, tied together on a joining strip; all five blacks go to battery negative (Electronics plan 6.7). No fuse: the 1k limits a short anywhere on the run to about 29 mA, and a blown fuse there could stop all charging. Coil on (shore command, 5 days at most unless renewed): all five chargers stop. A dead node, expander or feed drops the relay, and so does the node once neither Pi has been heard for the set time. Measure each run to its MPPT against the cable’s own length; if short, extend with 18/2 tinned wire on a screw terminal strip, no solder.

Channels 9 and 10. Channel 9 (camera port UV-C) leaves by entry 27 to the LM317 regulator and the UV-C lights at the camera port: small 275 nm LED boards above and below the lens, starting at 20 mA with a 62 ohm set resistor (the build: Underwater Camera Port Guide). Channel 10 leaves by entry 28 to the Orion-Tr’s remote on/off.

Release. Channels (Electronics sec 4.3): 1 and 2 the drogue lids (horn A here, horn B on Release Node B); 3 to 6 the four cord pullers; 7 to 9 Boat 2; 10 to 15 retired on Boat 1 (Boat 2 keeps one pull-pin); 16 retired. Relay channel 5 and the channel’s MOSFET must both be on, both from native Nucleo pins. The release bus has its own 12/2 feeder (on hand) on a 30 A breaker at the bar (stud 4), not the node’s 15 A feed, entering by its own entry, 2a in Appendix A3. Open: measure the 12/2 jacket, then size this gland and Release Node B’s (PG11 or PG13.5).

Each puller runs through its own DPDT reversing relay (it swaps the motor’s two wires): 24 V coil, 10 A, each in its own DIN socket with screw terminals, coils on channel 11, no coil diodes needed. The 1N5408 sits on the relay input side (MOSFET drain to the release bus), so it works both ways; the horns need none. Ahead of each relay, one slow-blow 5 x 20 mm fuse in a DIN fuse holder, sized at the bench test; each puller runs 64 s and stops. Release is forward only; reverse needs a shore test command, with ch 5 and the puller’s channel still on. Entries 3 and 4 carry two drogue fire pairs (14 AWG) plus four cord puller power pairs on two 18 AWG 4-core cables, one per pair of pullers (Mike, 2026-10-02); which cores ride which trunk is counted when the wires are cut to length at fit-out.

A4 · BMS box · v10.2

Vmembrane vent, wall micro USB,required 2 sense pairs 12-core shielded:SBMS0 taps W0 to W8and the XT1 pair XT1 pair JK’s 9 taps, 18 AWG 10-core DS18B20 chain ribbon 11-pin plug ELECTRODACUS SBMS0 the watchman: reads, controls nothing WiFi/USB add-on: micro USB green plug: shunts on 1 to 4, XT1 on 15 and 16 cell socket: a new 12-pin ribbon WINFORD BRK2X6-L-DIN ribbon to screw terminals, DIN rail W0 on 1 and 2 + shield drain, W8 on 10 to 12 JKBMS JK-B2A8S 2 A active balancer, talks to nothing own power pair: V- on W0, V+ on W8 BUTT SPLICES ×9 the JK harness to its 18 AWG 10-core B0 + V- at W0, B8 + V+ at W8 NO CHARGER WIRING no EXTIO4 pause, no VE.Direct cables, no bypass 4 3 6 1 split glandUSB to the hubbox (Sheet A1a)required PG9shunt senseleads, 2 pairsshunts on the + PG7DS18B20 chainto central nodeentry 18 PG13.5, 16 or 2118 taps, XT1,DS18B20 chainfrom battery box
A4 · BMS box · notes
THE BMS BOX AS BOUGHTBOLTED TO THE BATTERY BOX’S AFT WALLNO BUSMONITORING ONLY

What it is. The battery watchman, bolted to the outside of the battery box’s aft wall and never inside it. It watches and controls nothing: no wire to the chargers, no relay, no load. The SBMS0 reads all eight group voltages through its own nine tap wires, pack current through the 300 A shunt, solar current through the 100 A shunt, and pack temperature (its XT1 thermistor on pins 15 and 16 of its green plug). It streams them to Pi A through the Electrodacus WiFi/USB add-on board (a micro USB socket, its lead tied down right outside the plug) and the USB hub beside Pi A. That stream is required: the battery percentage comes from it, because the SBMS0’s pack shunt is the only battery current sensor aboard. The JK balancer evens out the eight groups through its own nine tap wires; it talks to nothing and controls nothing. No CAN, no RS-485.

Where. Four 1/4 in stainless bolts through the aft wall on the minus side, opposite the main fuse, at mid-height or above, where the inside of the wall faces only the 1.75 in air gap and the aft G10 plate, never the cells; never on a long side wall. Each hole bored oversize, filled with thickened epoxy and redrilled, each bolt bedded in sealant, fender washers inside, nylon lock nuts or blue Loctite; drill before the pack goes in (Battery Box Building Guide Parts 4 and 8). All its glands face down, each cable with a drip loop. It is IP65: spray, not standing water; a drowned BMS box only loses readings.

The SBMS0 side. Its tap wires land on a Winford BRK2X6-L-DIN ribbon breakout board on the DIN rail, fed from the SBMS0’s cell socket by a new 12-pin ribbon about 8 in long; the SBMS0’s own ribbon is not cut. Terminal number = ribbon wire number: W0 on 1 with a jumper 1 to 2 and the 12-core’s shield drain on 2 (the shield grounded at this end only), W1 to W7 on 3 to 9, W8 on 10 with jumpers 10 to 11 and 11 to 12; never more than two wires under one screw. The green plug takes the two shunt pairs (battery shunt on pins 3 and 4, solar shunt on 1 and 2) and XT1 on 15 and 16.

The JK side. Its 11-pin plug carries B0 to B8 and its own power pair, V- and V+ (10 to 40 V). Each harness wire joins a core of its 18 AWG 10-core cable with an adhesive heat-shrink crimp butt splice: at W0 the B0 and V- wires share one end of the splice, at W8 the B8 and V+ wires. Splices staggered and tied to the plate; the board still unplugs at its own plug. Set it up by phone over Bluetooth: LiFePO4, 8 cells.

Entries. Entry 1 carries the eighteen tap wires (the SBMS0’s nine and the XT1 pair on 11 cores of the 22 AWG 12-core shielded cable, the JK’s nine on its 18 AWG 10-core), and the DS18B20 chain, sleeved in adhesive-lined heat shrink so the gland seals on one round sleeve; the chain leaves by its own PG7, entry 6, to central node entry 18. Open: entry 1’s gland, PG13.5, PG16 or PG21; measuring the sleeved bundle settles it. Both shunts sit on the positive side of the main bus board, and only their sense leads come in, by entry 3: one twisted pair per shunt, each wire on a 30 AWG fuse link at its shunt end, since it sits at battery voltage. Powered from the pack per the SBMS0 manual. No humidity breakout (no reader in this box).

Monitoring only. No EXTIO4 wiring, no charge bypass, and no VE.Direct remote cables (they leave from the central node, Sheet A3 entry 22), so entries 2 and 5 are not drilled. The charge limits live in the five MPPTs’ own lithium profiles (27.6 V absorb, 27.0 V float, temperature compensation off). Nothing stops charging in the cold automatically: Pi A alerts shore below 33 F on any pack probe, and shore can send the 5-day charging stop (relay channel 8).

A5 · FSESC box · v10.2

DELETED, NEITHER BOAT

FSESC box: deleted, neither boat. Number kept so later numbers stay put.

A6 · Aft junction · v10.2

AFT JUNCTION BOX · A6 plastic, about 12 × 8 × 5 in, passive, no Nucleo FEED TERMINALS always-on 24 V · 6 switched runs in NAV LIGHTS ch 3, no relay here MOTORING RELAY 30 A, coil ch 7 DIN TERMINALS one fuse per post feed wind (5 V regulator here), bilge, encoder A; out to the trunk V membrane vent 4 3 5 post lightsPG7 windPG7 no podplugged to the network switch box, Sheet A6a, entry 10 switch 24 V, open: a jumper from here, or its own run from the main bus board 9 10 12 13 11 19 16 17 18 14,15 PG924 V feedalways on PG13.5 ×2switchedloads in6× 16/2 PG11Starlinkpower PG11em-trakwet lab PG11lightsgroup PG7bowlantern PG9bilgeleads PG9shaft rpmplugged PG7encoder A PG11 ×2trunk tocentral15 if needed network entries: none here; all on the switch box, Sheet A6a
A6 · Aft junction · notes
PLASTIC · ~12 × 8 × 5 IN · STERNON NO BUSPASSIVE, NO NUCLEONO NETWORK PARTS

What it is. The plastic aft junction box is a patch panel, not a computer: the post’s wind and light cables and the deck sensors land on DIN terminals with one fuse per post feed, about 14 entries (15 if the second trunk is drilled), plus the vent; measure the box before the wires are cut to length. It holds no network parts. Beside it sits the aluminum network switch box (Sheet A6a), which takes every network cable; the Ethernet surge protectors are on their own board near the deck (also Sheet A6a). The entry numbers are kept, so entries 1, 2, 6 to 8 and 20 to 24, which moved to the switch box, are not drilled here.

Open: the switch’s 24 V feed. The switch stays on the always-on house branch. Whether its 24 V is a short jumper from this box’s feed terminals to the switch box’s entry 10, or its own run from the main bus board, is still to settle; the dashed stub at the left of the drawing marks it.

Post and cables. The post carries exactly four cables: two cameras, wind, lights. The wind and light cables come into this box (entries 3 and 4); the two camera Cat6 runs go through the surge board to the switch box (Sheet A6a). AIS is below deck. Entry 5 is plugged: no weather pod. The post wind meter’s 5 V regulator (Pololu D36V6F5) sits in this box, just after the wind sensor’s fuse; it gets its terminal block at a workbench, then it is potted.

Switched power. Everything switched arrives from the central node on six 16/2 duplex runs through two PG13.5 glands: Starlink power (relay channel 1), the wet lab’s own line (2; it reaches the central node from its own 15 A breaker, by entry 29 there), the nav lights (3), the em-trak (4), the bilge pump 1 manual-on (6; pump 2’s, channel 12, rides a 16/2 run or the sensor trunk) and the motoring-white coil (7). The TSW202 is on no channel. The nav lights arrive already switched, on channel 3’s normally closed contact, lit from sunset to sunrise and by day too in fog mode: a dead node leaves the boat lit, and the node lights them by itself if neither Pi is heard for the set time. There is no photocell relay. The motoring whites add on through their own 30 A relay here, its coil on channel 7: on only when it is dark and the motor runs, and in fog mode whenever the motor runs.

Sensors. The two bilge Water Witch states ride the trunk to the central node’s opto board. Pump running is known from the Water Witch 24 V output, so the central node’s current-meter entry 17 is not drilled. There is no high-water sensor. One sensor trunk is likely enough (two Water Witch states, two manual-ons, encoder A, wind); count at fit-out.

Fit-out flag. Lighting leaves this box three ways in the schedule (post lights cable 4, lights group 11, the bow lantern feed 19). Settle the split, and where the stern light’s feed actually rides, when the wires are cut to length; relay channel 3 at the central node switches all of the nav lights either way.

A6a · Network switch box · v10.2

NETWORK SURGE BOARD on a bulkhead near the deck, where the outside cables first come inside; a board, not a box, outside both boxes SP: Ubiquiti ETH-SP-G2 surge protector (five, outdoor-rated) fwd camport 1 aft camport 2 fisheyeport 3 interiorport 4 StarlinkSFP 9 to lightning copper 6 AWG, 1 to 2 ft max SP SP SP SP SP short premade Cat6 runs down to the wall jacks NETWORK SWITCH BOX · A6a aluminum, glued to the hull, wired to nothing switch and supply clip to a DIN rail on a long side wall, not the floor 1 2 3 4 9 V membranevent patch cords, wall jack to switch port, 6 in to 1 ft; no coils in this box TELTONIKA TSW202 8 PoE + 2 SFP, 54.0 V in, always on, never on a relay ports 1 to 5 cameras · 6 light driver · 7 Pi A · 8 Pi B SFP 9 Starlink (copper SFP module) · SFP 10 spare 8 5 6 7 Pi Bport 8, UTP underwaterAxis, port 5 light driverport 6 Pi Aport 7 54 V MEAN WELL DDR-120B-48, 54.0 V 10 PG924 V feed, always on from the aft junction line: jumper or own run (open) network entries: bulkhead jacks, one per cable, outside faces greased and taped; drawn on top for clarity, but side or bottom walls only not drilled: 11 (no ground lead here) and 12 (SFP 10, a coupler only if wanted)
A6a · Network switch box · notes
ALUMINUM · 11.8 × 8.3 × 3.9 INBESIDE THE AFT JUNCTIONGLUED TO THE HULLNOT ON THE LIGHTNING COPPERNO BUS

What it is. The network switch box is a CXCESNS aluminum box, the same as the two compute boxes, beside the plastic aft junction box (Sheet A6) at the stern. Every network cable ends here: nine bulkhead jacks (RJ45 couplers; a tenth only if SFP 10 is used), the 24 V feed and a vent, about 10 entries in all. It holds only the TSW202 switch, its Mean Well supply and the SFP module: nothing lightning-related. Keep the box well above bilge water.

Mounting inside. The switch and its supply clip to a DIN rail on a long side wall, not glued to the floor: the TSW202 is 4.8 in (122 mm) deep and the box only 3.9 in. On the side wall the switch reaches about 4.8 in across the 8.3 in floor, plus about 1.2 in of plug, which leaves about 2.3 in to turn the patch cords. Heat goes from the rail to the box wall, the glued face and the hull: about 5 to 15 W in all. Right-angle patch cords at the switch ports (a short right-angle adapter at a port is fine where a straight plug cannot turn), each cord tied down within about 2 in of its plug. Open: which way the right-angle plugs must point; reading it off the switch, with the distance from the rail to the port face, settles it before the cords are ordered.

Wall jacks. Every network cable crossing a box wall comes in on a bulkhead jack, one per cable: the Alrhso panel couplers, zinc and plastic (fine on Pi B’s UTP run: its metal touches no wire or shield). The outside face sits in the hull’s salt air, and the jack’s cap seals only an empty jack. On each outside face: a thin smear of dielectric grease on the plug, plug in, then self-fusing silicone tape stretched to about twice its length, half-overlapped, from the jack’s threads over the plug and 1 to 2 in down the cable, with no gaps, and a drip loop below. Jacks go on side or bottom walls, facing sideways or down, never on the top (the drawing puts them on top only for clarity). Inside faces, within sealed boxes, need no tape. The same goes for the one jack on each of Pi A, Pi B, the Starlink enclosure and the light driver’s dry box: 13 in all.

The switch. The five camera runs, the PoE light driver, Pi A, Pi B and Starlink all meet the Teltonika TSW202 (8 PoE ports plus 2 SFP slots; PoE is power sent down the network cable). Port map: on the drawing. The switch is always on from the house branch, never on a relay: shedding it would blind Starlink and cut the Ethernet between the Pis. Cameras and lights save power by per-port PoE control through the switch’s Web API, read back over SNMP, firmware pinned. PoE budget on the 112 W Mean Well supply: cameras about 60 W set aside, plus the driver at 25 W (802.3at) or 12 W (802.3af); both fit, no supply upgrade.

Surge protectors: on their own board near the deck, in neither box. The five deck and near-deck cables (two post cameras, foredeck fisheye, interior camera, Starlink) each pass a Ubiquiti ETH-SP-G2 (outdoor-rated) on a small board on a bulkhead where they first come inside. Their grounds go to one small tinned bar; one 6 AWG lead runs short and straight from it to the lightning copper, a foot or two at most (Lightning Guide 6.2, 7.4). Open: where the copper runs near that bulkhead, and so which bulkhead takes the board; check at the boat. Short premade Cat6 runs go down to this box’s wall jacks, low in the hull; keep cables before and after the protectors apart.

Network cables are premade, none crimped aboard. Extra coiled near the surge board (small tight strapped coils about 8 in across, the camera side and the switch side apart); none in this box: 6 in to 1 ft patch cords, jack to port. No sharp bends at plugs; check each plug passes its holes and glands, or use a split gland (a gland that opens to close around a cable that already has its plug).

Open: the switch’s 24 V feed stays the always-on house branch; whether it is a short jumper from the plastic box’s feed terminals (Sheet A6 entry 9) or its own run from the main bus board to entry 10 is still to settle.

Cooling. This box is glued by its back face straight to the hull in the heat-carrying epoxy of Compute Bay 2.3, like the Pi A box; entries go on the other faces, with drip loops. It is wired to nothing and stays off the lightning copper list (Lightning Guide 6.2).

A7 · VESC A box · v10.2

FLIPSKY 75200 PRO V2.0 main propulsion · 250 kbps ID clear of J1939 · shorted switch plug COMM JST-PH 8-pin · CAN JST-GH 5-pin on an aluminum floor plate TVSon the 2 AWG feed 2 AWG 2 AWG ×3 UART + kill sin/cos +KTY84/130 C U + − Φ3 S PG7CAN controldrop PG7UART + killto Pi A PG16battery +2 AWG PG16battery −2 AWG PG16 ×3phases U V W1.0 in mix-31 clampover all three, outside PG7motor sin/cos+ KTY84/130Metri-Pack 150
A7 · VESC A box · notes
PURCHASED SEALED ENCLOSURECONTROL BUSCOCKPIT WEB, AT THE MOTORALUMINUM FLOOR PLATE (SIZE OPEN)

What it is. Main propulsion drive for the ME1616 motor: the Flipsky 75200 Pro V2.0, aluminum PCB, power-button variant, bought 2026-10-03 on Amazon (order 114-2434294-4539414), $160.99, here 2026-10-07; the 2026-09-05 PayPal order shows no payment, and if it turns up too, one goes back. A crimped shorted plug replaces its on/off button, so the board runs whenever battery is present. No precharge (Mike, 2026-09-29): the battery switch makes the first connection. Boat 1 sails with this one VESC; VESC B (Sheet A8) is Boat 2 only.

Plugs. COMM: JST-PH 8-pin, pairs on hand. CAN: JST-GH 5-pin leads, on hand (Kidisoii pre-crimped kit); CANH, CANL, GND only, PWR.ON open. Pin 1 found by meter at the bench check.

Eight holes. CAN; UART + kill; battery + and − (PG16 each, in through the TVS); three phase legs (PG16 each, drawn as one run) with the single 1.0 in mix-31 clamp over all three just outside the wall; sensor lead. Pi A holds a direct UART line with a hardware kill beside the CAN drop; the kill line is the hardware backstop under the jam logic in the Pi.

Motor sensor. The ME1616 sensor harness is built to the Sep 2 spec (crimp, no solder; SinCos encoder input). A 10k and 18k divider on sin and on cos, unless the bench check shows the tops stay under 3.2 V. The motor’s sensor plug is an Aptiv Metri-Pack 150, 8-way, sealed; its mating plug (an ELITE.CITI pair with terminals and seals for 20 to 22 AWG, $14.81) is ordered. Motor temperature sensor: KTY84/130; check the board has the 10k resistor the firmware assumes.

Power and cooling. Extra bus capacitance sits at the controller: four Nichicon 1,000 uF 63 V on a small G10 board on two insulated MGI SpeedWare 3/8 in posts, where the 2 AWG feed and the controller’s own 8 AWG leads land (Electronics plan A7). The Flipsky sits on an aluminum plate through the box floor, set in the heat-carrying epoxy and wired to nothing. Size the plate before the box is drilled, and check it against Lightning Guide 6.2’s one-connection rule.

A8 · VESC B box · v10.2

40 A CLASS VESC backup propulsion · 250 kbps TVSon the input CONTACTOR TERMS set / reset + sense coil fed from main bank 8 AWG to the phase-transfer contactor C + − Φ3 K PG7CAN housedrop PG13.5battery +8 AWG PG13.5battery −8 AWG PG16 ×3phases to thecontactor PG7contactor coilset/reset + sensefrom main bank
A8 · VESC B box · notes
PURCHASED SEALED ENCLOSUREHOUSE BUSBESIDE VESC ABOAT 2 ONLY, NOT FITTED ON BOAT 1

Boat 2 only, not fitted on Boat 1. Boat 1 sails with one VESC: losing propulsion costs time, not the trip, because the wing sails the boat. The backup VESC, the phase-transfer contactor, its set and reset coils and position sense are Boat 2 parts; no holes are drilled for this box on Boat 1. On Boat 1 there is one throttle path and the “propulsion_backup” software state is unreachable.

On Boat 2. The backup throttle: a 40 A class VESC on the house bus, feeding the same motor through the phase-transfer contactor, which picks whose phases reach the ME1616. The contactor coil is fed from the main bank (island rule); the set, reset and sense lines pass through this box’s terminals. House bus by design: with VESC A and the Electrak on control and VESC B on house, no single bus failure strands both throttle paths.

Holes. Seven, Boat 2 only (the Appendix A8 text says 8, but its own list adds to 7).

A9 · Battery box · v10.2

V Gore M12: aft wall no burst membrane FORWARD WALL, high: relief stub, 2 in hole saw 1-1/2 in Sch 40 PVC stub glassed in, PVC coupling Dometic 385310076 duckbill, lips out, discharge forward no screen on the stub 3.2 V each, 24 V nominal · XT1 on one cell face 18 taps + thermistor no separate balance gland no heater pads no thermal fuse DS18B20 CHAINpack probes: the battery trip 1 2 3 F J G H PG16 (2 AWG mains) main + out to fuse F PG16 (2 AWG) main − to the − bar PG13.5, 16 or 21 (open) signal bundle: 18 taps, XT1, 1-wire bolts, bedded 300 A main fuse, outside, mid-height, + side not drilled JK taps ride the bundle not drilled 1-wire rides the bundle not drilled no heater feed M 4 bolts, bedded BMS box, − side 8 GROUPS LiFePO4
A9 · Battery box · notes
PLYWOOD · MAIN BANKNO BUS · NO BRAIN INSIDEENTRIES HIGH ON THE AFT END WALL

What it is. Dumb by design: cells and sensors only. Every board that thinks lives next door in the BMS box. No CAN drop, no stop-wire relay, no data isolator at the box. Five holes, plus the main fuse’s bolts and the BMS box’s four bolts (M). Dashed circles on the drawing are holes that are not drilled.

Aft wall, high. Two PG16 (7/8 in) for the 2 AWG mains, in line with the terminal posts at measured post height so the cables run straight over the aft end plate. One gland for the signal bundle: eighteen tap wires, nine for the SBMS0 and nine for the JK, the XT1 thermistor pair and the DS18B20 chain. Open: that gland, PG13.5, PG16 or PG21; measuring the sleeved bundle settles it (Sheet A4). The Gore vent M12 (1/2 in) as the breathing inlet. Aft wall, outside, mid-height on the + side: the 300 A main fuse (F); bed any bolt through the wall in sealant. Opposite it, on the − side at mid-height or above: the BMS box (M), four 1/4 in stainless bolts, each hole bored oversize, filled with thickened epoxy and redrilled, each bolt bedded in sealant; drill before the pack goes in.

Forward wall, high: the relief stub. A 2 in hole-saw opening with a 1-1/2 in Sch 40 PVC stub glassed through, pointing up at 45 degrees into open cabin space. Inside it, a Dometic/Sealand 1-1/2 in toilet duckbill (OEM 385310076), lips out, flange clamped by a PVC coupling, discharge aimed forward away from the electronics. No screen on the stub: the duckbill is shut except when the box vents, and the cell-temperature trip is the protection. Not fitted: a bug cap or a fine flame mesh. None of these either: burst membrane, overboard duct, transom hole, flame screen.

No heaters. No pads, thermostats, thermal fuses or their wiring. Nothing stops charging in the cold automatically: no stretch of the route has a monthly-mean sea temperature below 35 F, the pack follows cabin air on its 2 in foam, and Pi A alerts shore below 33 F on any pack probe, so shore can send the 5-day charging stop (relay channel 8, Sheet A3).

Heat trip; no gas sensor (do not re-propose). The six DS18B20 pack probes carry the trip: 150 F on any probe, or a 10 F rise in five minutes, isolates the bank, HIBERNATE, alert. Release after one hour with every probe below 120 F. Warning-only alert at 131 F.

Taps. Each board has its own nine tap wires, each on its own ring and its own 30 AWG fuse link at the terminal end: 18 rings and 18 links, the two wires of each joint on two different posts of it. The bundle rides thick adhesive heat shrink at the gland pass, splits just inside into one branch per stack, and each branch is held by nylon cable clamps on short wood screws into the long wall, never tied to the cells. Build details: Battery Box Building Guide Part 8.

A10 · Emergency bank · v10.2

THE COMPARTMENT IS THE ENCLOSURE · NO BOX, NO GLANDS DYNESS 24V 100Ah LiFePO4 · 25.6 V · 2,560 Wh own plastic case built-in 100 A BMS 20.9 × 8.11 × 8.54 in · 42.6 lb +− 30 A ANLat the + post SMALL FUSED DIN STRIPbeside the battery, not in a box loads out charge in PI Bfeed out IRIDIUM Bfeed out SMARTSOLAR75/10 in ORION-TR24/24-5 in always on always on own panel main bus remote on/off ← central node relay ch 10, 90 minutes a day (Sheet A3) Restraint is the real work: 42.6 lb at 20.9 in long must hold in a knockdown and a full inversion. Chocked shelf, two straps over the top. Plastic case: nothing ties the island’s floating negative to the lightning copper. Boots on both posts.
EMERGENCY ISLANDNO BUSA BOUGHT BATTERY · NO BOX TO BUILD

The island’s own 24 V: a bought Dyness 24V 100Ah LiFePO4 (25.6 V, 2,560 Wh) in its own plastic case, with a built-in 100 A BMS, bought instead of a team-built 8 × EVE LF50 bank. No box is built and no gland is drilled: the compartment is the enclosure, and every wire lands on the battery’s M8 (5/16 in) posts or on a small fused DIN strip beside it. No hole schedule and no gland list (Electronics and Wiring Plan A10). The inline 30 A ANL, within a few inches of the positive post, protects the cable.

Two loads (Pi B and Iridium B) and two chargers. The SmartSolar 75/10 charges the bank from its two 50 W panels, even with the main bus or the node dead. The Orion-Tr 24/24-5 isolated charger (output 27.0 V) runs from the main bus 90 minutes a day and after the monthly exercise, switched through its remote on/off terminal by central node relay channel 10 on its normally open contact, so a dead node leaves it off. Its transformer is the only link to the main bank. Open with the maker: whether the built-in low-temperature cutoff blocks charging.

A11-A · Iridium A box · v10.2

Vmembrane vent MEAN WELL DDR-15G-5isolated 24 to 5 V, 3 A, DIN rail4,000 V input to output+ TVS at its input ROCKBLOCK 9603 carrier board 5 V P S X PG724 V, always on5 A breaker at bar PG7serial to Pi Aiso at Pi A PG7coax, LMR-240to the stub
PLASTIC, 5.9 x 5.9 x 3.5 INMAIN BANK · ALWAYS ONNEAR PI A

Voice number one. RockBLOCK 9603 on its carrier, fed always on from the main bank through an isolated 24 to 5 V converter (its 5 V side has no wire connection to its 24 V side) and a TVS. Isolated because the stub arrestor ties the coax shield to the lightning copper: the tie stops at the Iridium side, and the main negative is not tied to the copper a second time. The converter (Claude’s pick, 2026-10-09): a Mean Well DDR-15G-5 on a short DIN rail on the mounting plate, 9 to 36 V in, 5 V 3 A out against the RockBLOCK’s 0.5 A at most, 4,000 V between input and output; it stands about 2-1/2 in off the plate. The box: a TICONN IP67 ABS box, 5.9 x 5.9 x 3.5 in, with its mounting plate. Its idle draw is not published. Serial to Pi A (the ADuM isolator sits inside Pi A’s box); coax straight to the quarter-wave stub.

Feed: a 5 A breaker on its own stud at the main bus bar, 16/2 (Mike, 2026-09-28: a breaker comes back after a passing fault; a fuse would leave the voice dead). Coax: the stub arrestor is the only protection (no safing relays; a stub cannot wear out). It lands on the underside of the post’s copper deck terminal, a few inches from the deck stub. The coax comes below through the post’s 1 in deck stub with the GPS and Starlink cables. Antenna: on the aft deck beside the post, under its own clear acrylic dome on a white base plate, rubber gasket, with a 5/64 in (2 mm) weep hole at the low point (Instrument Post Guide 11.1; Electronics 6.5). The dome goes where no solar panel shades it and where it shades no panel.

A11-B · Iridium B box · v10.2

Vmembrane vent MEAN WELL DDR-15G-5isolated 24 to 5 V, 3 A, DIN rail4,000 V input to output+ TVS at its input ROCKBLOCK 9603 carrier board 5 V P S X PG724 V, always onfused at the strip PG7serial to Pi Biso at Pi B PG7coax, LMR-240to its own stub
PLASTIC, 5.9 x 5.9 x 3.5 INEMERGENCY ISLAND · ALWAYS ONNEAR PI B

Voice number two, the same inside but living entirely on the island: emergency-bank power, serial to Pi B through Pi B’s isolator, its own stub and dome. Its isolated converter keeps the island’s floating negative off the lightning copper, which the stub arrestor ties to the coax shield. The converter and the box are the same as Iridium A’s (Sheet A11-A). Nothing is shared with Iridium A, on purpose: a fault that silences one voice cannot reach the other.

Feed: fused on the emergency bank’s small fused DIN strip (Sheet A10). Antenna: forward on the foredeck under its own clear acrylic dome, built like Iridium A’s, with the same 5/64 in (2 mm) weep hole. Its coax comes below through its own small deck hole, so the two chains share no dome, deck hole, cable or fuse (Build Guide 8.3). The dome goes where no solar panel shades it and where it shades no panel. Arrestor lead: 6 AWG wire, about 6 to 7 ft aft to the lightning junction; measure where it lands before cutting the wire.

A12 · Detector mini-box · v10.2

Vmembrane vent SPARKFUN AS3935 lightning detector breakout power + data on one lead 1 PG77-core to WD-B, under 3 ft drip loop, no ferrite
PLASTIC, TINYEMERGENCY ISLANDWITHIN 3 FT OF PI B

One board, one hole. The AS3935 lightning detector hangs off WD-B on a short 7-core lead that carries its power and its data; inside the Pi B box the lead passes a 4-channel two-way level shifter (the detector works at 3.3 V, the Nano at 5 V). It logs strikes; WD-B never cuts Pi B’s power for lightning. The box touches no metal and is glued to a pad glued to the boat.

Open: bench the false-trigger rate with VESC A running before trusting it here. The fallback is a small forward node with an isolated transceiver.

A13 · Starlink enclosure · v10.2

STARLINK dish + its own electronics no heater element E P H RJ45Ethernet to TSW202jack, taped PG9powerrelay channel 1 no heater entrynot drilled
DECKSACRIFICIAL, NO ARRESTORRELAY CHANNEL 1

The broadband dish in its deck enclosure. Ethernet runs to the TSW202 at the aft junction (SFP port 9 through a copper SFP module), a long Cat6 run to the stern; its bulkhead jack’s outside face is greased and taped (Sheet A6a). Power rides relay channel 1 from the central node, so the Pi can shed it or power-cycle it. No enclosure heater: the dish has its own snow-melt heater. Declared sacrificial: no arrestor; losing it costs bandwidth, not the boat.

Deck hole: the instrument post’s 1 in PVC deck stub. The post bundle and the Starlink, GPS and Iridium A cables come below through that one stub and its 1 in liquid-tight flex conduit; no separate standpipes. Only Iridium B keeps its own small deck hole, under its forward dome, so the two satellite chains share no hole. Pass the bundle through a sample stub on the bench before the real one is glassed in; make up the coax connectors after the cables are through.

A14 · Native devices, no drilling · v10.2

CONTROL BUS HOUSE BUS EWELLIX CAHB-22 24 V DC, self-locking reversing drive + power-cut relay in the central node the Boat 1 part, confirmed ELECTRAK HD (Boat 2) Boat 2 only, unwired (island rule: never on the emergency bank) tee + cut-cable drop EM-TRAK B921 AIS transponder, N2K drop powered by a relay channel ch 4, fails ON tee + N2K drop NOT ON THE WING, NOT FITTED both packs, the four panels, the Genasun the pod Nucleo, both E32 radios the charging link: ROKK pad, Qi receiver, 12 V step-up, CC/CV board, SR560 the pod, its fuses and surge parts THE WING, THROUGH THE SLIP RING WING BOX, SMALL below the deck, at the hull entry a fuse or surge part at the entry of each of the eight ring wires: 5 A fuse + 1.5KE33CA, 3 Taidacent actuator on its own short CAN link, off the boat’s two buses 24 V NEGATIVE TERMINAL shield pigtail, brown pair, 3 Taidacent grounds open: material, vent, glands wing cable to the hub box (Sheet A1a): any shielded Cat6, all copper, plugs cut off blue pair CAN (H solid, L white) · orange pair tip meter RS-485 · green pair compass RS-485 (A solid, B white) · brown pair ground shield grounded here only, its pigtail on the 24 V negative terminal; at the hub box trimmed back and sleeved, touching nothing can wall CAN pair 24 V pair RS-485 pair compass RS-485 IN THE CAN SLIP RING Rion HC2549, IP65 eight wires across ON THE WING (TURNS) THOMSON ELECTRAK MD trim actuator, its own CAN MD24A025-0050CNO CALYPSO CMI1017 wing-tip wind meter, RS-485 5 V made at the tip, 1 A fuse WITMOTION HWT905 wing compass, own RS-485 on the tip’s 24 V, 1 A fuse
A14 · Native devices, no drilling · notes
SEALED FROM THE FACTORYTEE + DROP EACHWING BOX: GLANDS OPEN

What it is. Bought devices with their own sealed housings and connectors: no box of ours, no holes of ours. Each takes a tee on its backbone and a cut-cable drop into its own connector. The Ewellix CAHB-22 has no bus: its cable runs to the central node (Sheet A3, entries 12 and 13). The Electrak HD tee is Boat 2 only.

The wing (Wing Power System sec 1A). It reaches the hull through a sealed slip ring in the can (sliding contacts that pass wires across a turning joint), and its wires land in a new small wing box below the deck, where the wing's wires enter the hull. Eight ring wires: the Electrak MD’s 24 V and CAN pairs, the tip meter’s RS-485 pair and the wing compass’s RS-485 pair (on the ring’s two spare power rings). At the tip the 24 V pair feeds a branch on its own 1 A inline fuse: the compass runs on that 24 V (9 to 36 V), and a small converter makes 5 V from it for the tip meter alone (never 24 V on the meter). The compass (WitMotion HWT905, on the tip cap) gives the wing’s turn rate and, against the hull’s heading, its angle; there is no angle sensor in the can. The ring’s fixed-side cables leave the can by its wall gland and go down through their own deck gland straight into the wing box below the deck (Mike, 2026-10-02), where each ring wire gets a fuse or surge part (three Taidacent modules and the 24 V pair’s 5 A fuse and 1.5KE33CA), so a mast strike stops there. Nothing in the wing box thinks: one shielded 4-pair cable runs on to the USB hub box beside Pi A (Sheet A1a), carrying the actuator’s CAN pair, the tip meter’s and the compass’s RS-485 pairs, each after its surge module, and a ground pair tied to the wing’s 24 V negative in the wing box (the isolated readers’ signal side floats, so it must share a reference with the sensors). The cable is any shielded Cat6, all copper, with a shield over all four pairs, plugs cut off (Mike, 2026-10-09; Wire and Cable Buy List C8): blue the CAN pair (CAN H solid blue, CAN L blue-white), orange the tip meter’s RS-485 (A solid, B white), green the compass’s RS-485 (A solid, B white), brown the ground, both wires together; same colors and labels at both ends. Its shield is grounded at the wing box end only (Mike’s OK, 2026-10-09): the braid (or drain wire) twisted into a short pigtail, sleeved in heat shrink, on the box’s 24 V negative terminal, where the brown pair and the three Taidacent modules’ ground terminals also land (each module’s ground goes to that negative, as the battery bus surge modules’ do, so the boat keeps its one bond wire); any pair foils folded back and trimmed. At the hub box the shield is trimmed back flush and sleeved, touching nothing. The strike comes in at the wing box, so the shield drains there; grounded at the hub end it would carry the surge into the box beside Pi A, and grounded at both ends it would close a loop through the boat’s wiring. There the Waveshare 2-channel RS-485 reader takes the tip meter and the compass, and the DSD TECH SH-C30G isolated USB to CAN adapter talks to the actuator on its own lead to Pi A. RS-485 terminators off. The wing’s program runs on Pi A. The ring is the Rion HC2549, paid $495 (Mike, 2026-10-01).

The wing box’s wall: in, its 24 V feed (16/2 on its own 5 A breaker on the branch bar, then the box’s own 5 A fuse); in, the hull cables from the slip ring; out, the cable to the hub box. Open: the box’s material, whether it takes a vent, and each entry’s gland; picking the box and the cables settles them. Open: how many hull cables carry the ring’s eight wires; the cable choice settles it. Open: which stud feeds it, the end stud or stud 3; Mike’s call settles it.

A15 · Release Node B · v10.2

Vmembrane vent, wall 24 V TO 5 VKlnuoxj, potted FUSEown branch NUCLEO-G431KBscrew carrier, stakedall logic under screws CAN TRANSCEIVERbreakout + DIN surge module ENABLE RELAY24 V 30 A MOSFET MODULES ×22 release channels (horn B) MINI DIN STRIP: EVERY FIELD WIRE LANDS HERE 5 V 24 V, fused release bus enable coil · release gates 2 1 3 4 5 6 7 PG11 or PG13.524 V feed12/2, size open30 A breaker at bar PG7CAN housedropfrom end tee PG7drogue box 1node-B channel PG7drogue box 2node-B channel no pull-pinnot drilled no pull-pinnot drilled 7, 8: no optonot drilled
A15 · Release Node B · notes
PLASTIC, SMALLHOUSE BUS ENDSTERN, NEAR THE TRANSOM BOXESSECOND RELEASE CHAIN

What it is. The backup for the central node’s releases. Its own fuse, its own enable relay, its own MOSFET pairs and the same two-condition lock, commanded over the house bus, so no single bus or box failure silences every release. No shorting relays and no opto board: four entries (CAN, 24 V, drogue 1, drogue 2) plus the vent, and five Nucleo pins; entries 5 to 8 are not drilled. It releases the horn-B channel of each drogue box; either node alone cuts a drogue strap.

Same rules as the central node. Unpowered, it cannot release. Two separate conditions: the enable relay closed and the channel MOSFET on. No humidity breakout; no ferrites. No short relays, no opto board, no continuity or confirm readback. The monthly enable relay exercise covers this node.

What makes it independent. Five separate layers; a fault has to cross all five to take both paths to one device. Different bus: the central node is on the control backbone, this node on the house backbone, each with 12 V on its pair, fed once from its own 5 A breaker at the main bus board and its own 24 to 12 V converter at the compute multiport, with its own tees and terminators. Different power: a house-side branch with its own fuse. Different parts inside: separate Nucleo, firmware instance, converter, enable relay, release bus and MOSFET modules. Different holes and routes: its cables leave through their own glands and travel a different path to the same device, so one chafe point cannot take both paths. Different half of the device: each drogue lid carries two channels (horns A and B), and either one alone does the job. Still shared: Pi A, which commands both, and the main bank, which feeds both.

What the two conditions are. Not two brains agreeing, but one brain doing two physically separate acts: close the enable relay, the only thing that puts 24 V on the release bus, and turn on that channel’s MOSFET, the only return path to ground. Idle, the release bus is dead metal and the return is open. An enable timer drops the bus again if a release command never arrives. That defeats a welded contact, a shorted MOSFET, a stray 24 V wire landing on a release terminal, or a wet terminal block. It does not defeat a Nucleo gone haywire, which is why the drogue and JSD paths also need a signed ground command and have no automatic path at all.

The honest cost of the split. Two chains double the odds a lid opens when it must, and double the number of boxes that can open it when it must not. What holds that second risk down is the signed ground command and the enable timer. There is no idle short across the burn wires: the dead release bus and the open MOSFET are the two conditions.

A15 · Release Node B · one release channel traced
ONE RELEASE CHANNEL, TRACED · DROGUE LID SHOWN box wall NUCLEO-G431KB one chip, two separate acts 24 V HOUSE branch, own fuse ENABLE RELAY condition 1 RELEASE BUS · dead metal until enabled BURN WIRE across the lid strap NC SHORT RELAY not fitted, either node MOSFET SWITCH condition 2 · low side condition 1: ENABLE condition 2: RELEASE n No enable and the bus is dead metal. No gate and there is no way back to ground. Neither act alone does anything, and with the box unpowered neither act is possible. PG7 · 2-core, one gland
The two conditions drawn out. Amber is 24 V, heavy red is the release path, blue dashes are the two logic lines from the Nucleo. The ghosted block is a normally closed shorting relay across the burn wire, not fitted on either node: the release bus is already dead until the enable relay closes, and each channel also needs its MOSFET on.

A16 · Transom terminal box · v10.2

Vmembrane vent, wall DIN STRIP: ONE LANDING PER CONDUCTOR · LABELS BOTH ENDS trunks in 1 2 3 4 5,6 7 8,9 10 PG11trunk 1 infrom A3 PG11trunk 2 infrom A3 PG9drogue box 1node-A ch PG9drogue box 2node-A ch PG11 ×2JSD cord pullercables outone 18/4 each aux-rudderBoat 2 onlynot drilled pull-pinsnonenot drilled PG9bridle switchesdeletedplugged
A16 · Transom terminal box · notes
PLASTIC · ~12 × 8 × 5 IN · ON HANDNO BUS · NO ELECTRONICSSTERN

What it is. A DIN strip in a box, nothing more. The central node’s two release trunks land here and fan out to the drogue boxes and the JSD cord pullers ×4 (24 V worm-gear motors, one per T8 trigger). The aux-rudder release is Boat 2 only and unwired; there are no pull-pin stations. No electronics, so nothing to fail.

Why it stays passive. Like the aft junction, a box death here is a wiring fault, not an electronics fault, and every conductor can be checked at the strip. Each conductor gets one landing and a label at both ends, so a stern fault is found with a meter at the strip instead of by pulling a trunk. The fuses stay forward at the central node end of the trunks, so nothing in here can fail while powered. Chafe-sleeve the trunks where they enter, drip loops on everything, no ferrites.

What it buys, and what it costs. Nothing electrical. It turns four long runs from the central node (forward, by the battery and the busbars) into two trunks plus four short tails, and keeps about two holes out of the central node wall. The cost: two extra screw joints on every conductor, in a plastic box on the transom, on the one circuit where a bad joint cannot be recovered. Whether that is worth it comes down to the trunk core count, still open in Pending Amendments. The trunks carry the two drogue fire pairs plus four cord puller power pairs, about 12 cores (the puller reverse is done inside the central node, so it adds no wires aft). At twenty-plus conductors the trunks clearly win; at a dozen, direct runs are competitive and the joints go away. Compare Sheet A15, which runs direct to the same stern devices with no strip in between.

WHAT LANDS WHERE · CORE COUNTS OPEN: SEE PENDING AMENDMENTS TRUNK 1 from central node TRUNK 2 from central node DROGUE 1 release pair DROGUE 2 release pair CORD PULLERS ×4 4 power pairs AUX RUDDER Boat 2, unwired PULL-PINS none on Boat 1 BRIDLE deleted 3 4 5,6 7 8,9 10 PG9 PG9 PG11 ×2 not drilled not drilled PG9, plugged Trunks: two drogue node-A fire pairs (14 AWG) plus four cord puller power pairs on two 18/4 cables; count when the wires are cut to length at fit-out. No confirms, bridle switches or sense lines: the speed drop and the aft camera confirm the drogue is out.

R1 · Release path map · v10.2

PI A signed ground command required CONTROL BUS HOUSE BUS CENTRAL NODE sheet A3 · control bus · forward by the battery ENABLE RELAY condition 1 MOSFET ×n condition 2 NC SHORT not fitted release readback deleted RELEASE NODE B sheet A15 · house bus · stern ENABLE RELAY condition 1 MOSFET ×2 condition 2 NC SHORT not fitted OPTO not fitted TRANSOM TERMINAL BOX · SHEET A16 passive DIN strip, two trunks in NODE-A FAN-OUT NODE-B DIRECT RUNS CORD PULLERS ×4 release ch 3 to 6 ONE PATH ONLY AUX-RUDDER ch 7 to 9 reserved BOAT 2, UNWIRED DROGUE LID 1 ch 1 + node-B ch either alone cuts DROGUE LID 2 ch 2 + node-B ch either alone cuts PULL-PINS ch 10 to 15 retired Boat 2 keeps one BRIDLE SWITCHES deleted entry 10 plugged Solid = node A: control bus, central node, two trunks, transom strip, short tails. Dashed = node B: house bus, Release Node B, direct runs on their own glands and their own routes. No short relays and no release readbacks on either node: the speed drop and the aft camera confirm a drogue deployment.
R1 · Release path map · notes
NO BOX · SYSTEM VIEWREAD WITH A3, A15, A16CORD PULLERS: SINGLE PATH

What it shows. For every releasable device: which chain can release it, and what has to die before nothing can. Solid lines are the node-A chain on the control bus, through the passive transom strip. Dashed lines are the node-B chain on the house bus, running direct.

The main point. The two drogue lids have two chains; the JSD cord pullers ×4 (24 V worm-gear motors, one per T8 trigger) do not. The pullers are driven only by the central node and reach the stern only through the transom terminal box, so the trunk, the strip and the node are three single points in series. A second path for them would need four more channels and new runs to the stern. They can be run backward for testing from shore through relay channel 11 (Sheet A3).

Channel numbers are owned by the Electronics and Wiring Plan sec 4.3: 1 and 2 the drogue lids (horn A central node, horn B Release Node B); 3 to 6 the four JSD cord pullers (central node); 7 to 9 reserved for the Boat 2 aux rudder (unwired); 10 to 15 retired on Boat 1 (Boat 2 keeps one pull-pin); 16 retired (trim decouple, not on this sheet). Pi A commands both chains, so the Pi and the main bank are the two things this split does not protect against; everything after them is doubled for the two drogue lids.

DevicePath APath BIf one chain is lost
Drogue lid 1Central node ch 1, trunk, transom strip, entry 3Release Node B, direct, entry 3Either channel alone cuts the strap
Drogue lid 2Central node ch 2, trunk, transom strip, entry 4Release Node B, direct, entry 4Either channel alone cuts the strap
JSD cord pullers ×4Central node ch 3 to 6, trunk, transom strip, entries 5 and 6noneNo release: node, trunk and strip are all in series
Aux-rudder release, Boat 2 only, unwired (ch 7 to 9 reserved)Central node ch 7 to 9, trunk, transom strip, entry 7noneNo release: same three in series
Pull-pins (ch 10 to 15) retired; bridle switches deleted, entry 10 plugged

Path A entry numbers are Sheet A16 entries; Path B entries are Sheet A15 entries. Release Node B has no opto board and no short relays: four holes and a vent.

Fit-out flags: what is still open

The open questions that touch the wiring live in one place, Pending Amendments v10.3 (the open list). On these sheets they are:

Boxes and glands. The USB hub box itself (to buy: its material, and so whether it takes a vent) and the gland for each of its entries (A1a). The wing box’s material, vent and glands, and how many hull cables carry the slip ring’s eight wires (A14). The battery tap bundle’s gland at both ends, PG13.5, PG16 or PG21, once the sleeved bundle is measured (A4, A9). The release feeder glands, PG11 or PG13.5, once the 12/2 jacket is measured (A3, A15). The aft junction box size (A6).

Feeds and parts. Which bus bar stud feeds the hub box and the wing box, the end stud or the stud table’s 8 and 3 (A1a, A14). The emergency bank DIN strip’s fuse sizes for Pi B, Iridium B and the 75/10 (A10). The switch’s 24 V feed, a jumper from the aft junction or its own run (A6, A6a). The SBE 45’s serial type, RS-232 or RS-485, read off its label on arrival (A1).

Routing and fit. Which way the switch’s right-angle patch cords must point (A6a). Which bulkhead takes the network surge board, near where the lightning copper runs (A6a). The aluminum cooling plate through the VESC A box floor (A7). The camera port’s UV-C lights (a factory-made board, or the small boards on trial). Which release trunk carries which cores (A3, A16). The lighting exits at the aft junction (entries 4, 11 and 19 all carry lighting).

The decided items are drawn in on their sheets.

Back to the sheet index ↑