One drawing per box: what lives inside it, how the pieces wire to each other, and every cable through the wall. Companion to the Electronics and Wiring Plan; entry numbers and gland sizes match Appendix A hole for hole. Every decision in the v10.2 guides is drawn in, the slip ring through the wing’s turning joint among them.
How to read a sheet. The heavy outline is the box wall. Blocks inside are the boards and parts that live in the box; colored lines are the wires between them. Numbered circles on the wall are the cable entries, numbered exactly as in Appendix A of the wiring plan, with the gland size under each and where the cable goes just below. Every entry is a nylon IP68 gland unless it is marked as an RJ45 coupler or an SMA bulkhead, and only cables that leave the cabin get a mix-31 ferrite, on the outside (Electronics and Wiring Plan sec 7.5). Entry positions on these sheets are drawn for readability; the real holes go where the drilling templates put them.
Printing. US letter, landscape. Each sheet prints as its drawing on one page and its notes on the next; the simplest boxes (A5, A10 to A13) fit drawing and notes on one page.
| Sheet | Box | Holes |
|---|---|---|
| 0 | The whole network, box to box | |
| A1 | Pi A box (aluminum, main island, lightning stud) | 10 + V + B (S and 7 share one split gland; 12, S, 7 to the hub box) |
| A1a | USB hub box (beside Pi A; the hub, science adapters, dAISy and wing readers; box not picked) | 6 + one 5-port split gland (+ V if plastic) |
| A2 | Pi B box (aluminum, backup island, floats) | 8 + V |
| A3 | Central node (release, two relay modules, the charging stop, the Ewellix steering drive) | 15 + 2a + V (one more if entry 15 is needed) |
| A4 | BMS box as bought, on the battery box’s aft wall (watchman; monitoring only) | 4 + V |
| A5 | FSESC box: deleted, neither boat | none |
| A6 | Aft junction (plastic, passive, stern; nav lights arrive switched, no photocell; no network parts) | ~14 + V (measure the box) |
| A6a | Network switch box (aluminum, beside the aft junction, glued to the hull; the TSW202 switch and its supply only, on a DIN rail), with the network surge board near the deck (the five Ethernet surge protectors, not a box) | 10 + V |
| A7 | VESC A box (main propulsion) | 8 |
| A8 | VESC B box: Boat 2 only, not fitted on Boat 1 | 7 (Boat 2) |
| A9 | Battery box (main bank) | 3 + V + relief stub + fuse, BMS box bolts |
| A10 | Emergency bank: a bought Dyness battery, no box to build | none |
| A11-A | Iridium A box (main island) | 3 + V |
| A11-B | Iridium B box (emergency island) | 3 + V |
| A12 | Detector mini-box (AS3935) | 1 + V |
| A13 | Starlink enclosure (deck) | 2 + deck stub |
| A14 | Native devices, no drilling; the wing through its slip ring into the new wing box below the deck, where the wing's wires enter the hull | tee + drop; wing box: at least 3 |
| A15 | Release Node B (second release chain, stern) | 4 + V |
| A16 | Transom terminal box (passive fan-out; entry 10 plugged) | 6 + 1 plugged + V |
| R1 | Release path map: which node releases what | no box |
What it shows. Two CAN rails, one Ethernet star, and one floating island. Steering and release channels ride the control bus; the busier monitoring traffic rides the house bus. Only the Pis touch both rails. Boat 1 steers with one actuator; there is no FSESC box.
Bus power. Each bus carries 12 V on its power pair, fed once from its own 5 A breaker at the main bus board and its own 24 to 12 V converter at the compute multiport.
Emergency island. Pi B, Iridium B and the lightning detector run on the emergency bank with no copper path to the main system. Every one of their data links crosses on an isolator, a transformer, or plain UTP (unshielded network cable), whose bulkhead jack’s metal touches no wire or shield. The one power bridge is the Orion-Tr, a charger isolated by its own transformer, which central node relay channel 10 runs 90 minutes a day.
Bus order as built. Control: power tee, 4-port multiport (Pi A, Pi B), VESC A, central node. The Electrak tee is Boat 2 only and unwired; Boat 1 steers with the Ewellix CAHB-22, a plain DC actuator driven from the central node, not a bus device. House: power tee, multiport, em-trak, VESC B (Boat 2 only; its tee is unwired on Boat 1), and Release Node B as the bus end. The aft junction is on no bus: nothing in it talks on CAN. The terminators (the 120 ohm end resistors) sit on the spare port of the end tees; HAT termination jumpers off.
Also shown. Release Node B (Sheet A15) at the stern, with the passive transom terminal box (Sheet A16) beside it, on no bus. The USB hub box beside Pi A (A1a), the Orion-Tr (A10), and the wing on its slip ring, no radio, into the wing box below the deck (A14). The wing box sends one shielded 4-pair cable to the hub box, where Pi A reads the tip wind meter and the wing compass and talks to the trim actuator on the actuator’s own CAN link, kept off both buses.
What it is. The main brain. Glued to the hull below the waterline for cooling, at least 2 ft from the main battery and motor cables where space allows, for the IMUs (a guess at a safe distance); bond stud wired to the lightning copper. Entries go on any face but the glued back face, with drip loops (drawn on the bottom). Every line from off the island crosses an isolator or an optocoupler before it touches the CM5.
Power. The 10 A breaker at the bar (entry 1), then inside: the TVS, the INA226, the terminal strip, WD-A’s relay and the Mean Well DDR-60L-5 converter (5 V 12 A, 18 to 75 V in, isolated, on a short DIN rail at the far end of the plate from the IMUs; output set to 5.1 V, output negative tied to input negative), then the carrier. The relay is a 5 V 1-channel module with Pi A’s 24 V feed through its normally closed contact, ahead of the converter: coil off means Pi A on, so a dead Nano leaves Pi A running. WD-A cycles Pi A after five minutes of heartbeat silence. WD-A runs on its own Pololu D36V6F5, fed ahead of the relay, so the relay never cuts it. The hub’s 5 V lead takes off the converter’s output on a 3 A inline fuse and leaves by entry 12, so the hub restarts whenever WD-A cycles Pi A.
Entries. Eleven, plus the vent and the bond stud: 1 to 8, 11, 12 and S. Not drilled: 9 and 10 (Pi B and Starlink run to the TSW202), 13 (no wing radio) and 14 (no RTL-SDR). One mix-31 ferrite, on the GPS A coax only. The CAN shield drain lands on the bond stud here and nowhere else. Entry S carries the hub’s USB lead to Pi A’s first USB port, with no USB isolator; entry 7 the wing CAN adapter’s own lead to the second; S and 7 share one Altelix PG25 4-port split gland (on hand; two ports plugged), so both USB plugs pass without cutting (Pending 423); the adapter’s lead goes never a hub port, so the wing’s control never depends on the hub. The kill line (entry 4, beside the VESC UART) and the alive line to Pi B (entry 6) leave WD-A through a HiLetgo PC817 optocoupler board. The Ethernet bulkhead jack’s outside face is greased and taped (Sheet A6a).
Inside. Two IMUs, A1 and A2 (BNO085), on the same I2C pair, A2 at the chip’s second address, one at each end of the plate, far from the converter, each with a forward arrow on the plate. The safe-mode wire runs from a WD-A output pin to header pin 37, the 15k in the wire and the 22k from pin 37 to ground, so the pin sees about 3 V, not 5 V; no box hole. Pi A’s motor kill pin, when assigned, must not use pin 37. Vent, desiccant, humidity breakout; boards conformal-coated. The 4 TB NVMe and the Hailo-8L go in the carrier’s two M.2 slots; bench-prove both. GPS A is a NEO-7M, position only. USB cables clamped within 2 in of their plugs, plug bodies staked. FTDI chips only, never CH340.
USB hub box. Now on its own sheet, A1a: the hub, the science adapters, the dAISy and the wing’s two readers. Three leads link it to Pi A: the hub’s 5 V lead (entry 12), the hub’s USB lead (entry S) and the CAN adapter’s lead (entry 7).
What it is. A small box of its own beside Pi A (Electronics plan A1a), because Pi A’s box is full. It holds the USB hub and everything that plugs into it, plus the wing’s two readers. It is on no bus: its only links to the computer are two USB leads to Pi A.
Power. Two feeds. The hub runs off Pi A’s 5 V: a short 2-core lead from Pi A’s Mean Well, on a 3 A fuse inside the Pi A box, out by Pi A entry 12 and in by this box’s top PG7 gland, so the hub restarts whenever WD-A cycles Pi A. The box’s own 24 V feed (16/2 on its own 5 A breaker at the branch bar) feeds only the third YRDZXG 24 to 12 V converter, with no fuse on either side of it: the 5 A breaker is the only protection (Mike, 2026-10-14, Pending 426); the 12 V goes out with the SDI-12 line to the BaroVUE 10 and HygroVUE 10, never the 24 V bus.
The hub. StarTech USB210AIND, 10 ports, DIN rail, 5 to 24 V in on a terminal block. Its ports: the SDI-12 adapter, the SBE 45’s FTDI USB-RS232-WE-1800-BT-0.0 cable (RS-232, Mike 2026-10-14; the 0 V version, no power out on its wires), the DO sensor’s FTDI cable, the Waveshare wing reader, the dAISy, the SBMS0 lead and the MOTU M2; three spare. Its own USB lead is detachable: clamp and stake it at both ends.
Leads that keep their plugs (Pending 423, Mike 2026-10-14) go through one Altelix PG25 5-port split gland in the top wall: the hub’s lead and the CAN adapter’s lead to Pi A, the SBMS0 lead from the BMS box, the AIS antenna coax with its PL-259 on, and the MOTU M2 lead if the MOTU sits outside (else that port takes its plug). The cable lays into a slit seal from the side, so no USB plug is ever cut off. Lines with a bare wire end (the DO sensor, the SBE 45, SDI-12, the wing cable, the 24 V feed) go through ordinary glands in the bottom wall, the wire end fed in from inside.
AIS. The dAISy 2+ has a BNC antenna socket and a mini USB port (Pending 422). The Eifagur stubby VHF antenna’s 16 ft of RG-58 ends in a PL-259; it screws into a Superbat 1 ft SO-239 to BNC jumper, whose BNC end plugs into the dAISy. A flexible jumper, not a solid adapter, so the coax’s weight never levers on the dAISy’s socket. No SMA bulkhead and no SMA to SO-239 jumper. AIS from the dAISy depends on the hub; the em-trak is the second receiver.
The wing. The wing cable from the wing box (Sheet A14) is any shielded Cat6, all copper, plugs cut off. It lands on a terminal block: blue the trim actuator’s CAN pair, to the DSD TECH SH-C30G (120 ohm switch on); orange the tip meter’s RS-485 and green the compass’s, to the two channels of the Waveshare USB TO 2CH RS485 reader (terminators off); brown the ground, tied to the wing’s 24 V negative in the wing box and here landed on each adapter’s ground terminal. The shield is grounded at the wing box only: here it is trimmed back and sleeved, touching nothing. Both readers are isolated, so a strike on the wing stops at them. The CAN adapter’s lead goes straight to Pi A’s second USB port, never a hub port, so the wing’s control never depends on the hub.
Rules. FTDI chips only for serial, never CH340. Every USB plug clamped within 2 in and staked. No USB isolator (one 5 V supply: it would isolate nothing). Not fitted: the DROK 24 to 5 V converter bought for the hub, and a relay to cycle the hub alone. If the hub drops off, Pi A tries a USB reset, then stops its heartbeat so WD-A cycles Pi A and the hub together.
Open: the box itself (its material, and so whether it takes a vent) and each bottom gland’s size; buying the box settles them. Open: which bus bar stud feeds it, the end stud or stud 8. Open: where the MOTU M2 sits.
What it is. The backup brain, a few feet from Pi A on the settee panel, electrically nowhere near it. Power comes from the emergency bank only, through a fuse, a terminal strip, WD-B’s relay and its own potted Klnuoxj 24 to 5 V converter with TVS, the negative left floating (tied to nothing). The relay is a 5 V 1-channel module with Pi B’s 24 V feed through its normally closed contact, ahead of the converter: coil off means Pi B on, so a dead Nano leaves Pi B running. WD-B runs on its own Pololu D36V6F5, fed ahead of the relay, so the relay never cuts it. Every data link crosses on something that does not conduct: the CAN HAT’s isolation, the Ethernet jack’s transformer, an ADuM isolator chip on the Iridium B serial line, and a HiLetgo PC817 optocoupler board on the alive signal from Pi A. WD-B owns the whole lightning role and reads the AS3935 detector on a short 7-core lead, through a 4-channel two-way level shifter inside this box (the detector works at 3.3 V, the Nano at 5 V). WD-B never cuts Pi B’s power for lightning.
The five isolation rules, drawn. 1) Emergency-bank power only. 2) Every data link optical or transformer coupled. 3) No metal shell or shield ties this box to Pi A: plastic glands, plain UTP (unshielded network cable), so the Alrhso bulkhead jack’s zinc and plastic body touches no wire or shield; its outside face greased and taped (Sheet A6a). 4) No bond stud. 5) Everything else on the emergency bank (Iridium B, detector, WD-B) lives on this side. Entry 7 stays blank.
What it is. The one team-built node: a Nucleo, screw-terminal boards and a DIN rail where every field wire lands first. It fires the releases, switches the loads, holds the charging stop, drives the Ewellix and reads the sensors. Print the relay map (Compute Bay Plan sec 11, table below) on the lid.
Reading the drawing. Red: relay channel 5, the release enable relay. Amber: channel 8 (charging) and channels 9 and 10. Dashed blue: logic lines. Dashed circle: the release feeder, entry 2a. Entry 29 (top) brings the wet lab’s own 16/2 line in from its 15 A breaker to channel 2; it leaves on one of the six runs aft. Entry 30 (top right) takes the horn’s 16/2 pair from relay channel 13, through its 5 A inline fuse, to the horn low on the instrument post. The charging stop’s 1k resistor sits at the main bus board (dashed box). Not drilled: 17, 20, 21 and 23 to 26 (17, 20 and 25 are spares, drilled only when a cable needs one); entry 15 only if the count needs it.
| Relay ch | What it switches | Contact | Coil driven from |
|---|---|---|---|
| 1 | Starlink power | Normally open | Expander |
| 2 | Science payload group: the wet lab’s own 15 A line, in by entry 29 | Normally open | Expander |
| 3 | Nav lights (bow lantern, stern light), sunset to sunrise, and by day too in fog mode | Normally closed: a dead node leaves the boat lit | Expander |
| 4 | em-trak AIS transponder | Normally closed: fails ON | Expander |
| 5 | Release enable relay: feeds the release bus | Normally open: dead, the bus is dead | Native Nucleo pin |
| 6 | Bilge pump 1 manual-on | Normally open | Expander |
| 7 | Motoring whites (coil of the aft junction’s 30 A relay): on only when dark and the motor runs; in fog mode, whenever the motor runs | Normally open | Expander |
| 8 | Charging relay: coil on stops all five chargers | Normally closed: dead, the chargers run | Expander |
| 9 | Camera port UV-C, 5 min on and 10 off, in software | Normally closed: a dead node leaves the UV on | Expander (module 2) |
| 10 | Orion-Tr on/off: 90 minutes a day, and the monthly recharge | Normally open: a dead node leaves it off | Expander (module 2) |
| 11 | Cord puller reverse (test): coils of the four reversing relays | Normally open: dead, the pullers run forward only | Expander (module 2) |
| 12 | Bilge pump 2 manual-on, and its monthly 5-second dry run | Normally open | Expander (module 2) |
| 13 | Horn: its 24 V through a 5 A inline fuse, out by entry 30 to the post; shore command, and one long blast every 2 minutes in fog mode | Normally open: a dead node leaves it silent | Nucleo pin A2 (native) |
| 14 to 16 | Not used as relays. The expander pins of 13 to 16 read the Water Witch states, the release bus readback and the G2 fault | none | Expander inputs |
Steering and sensors. The Ewellix CAHB-22 runs from a Pololu G2 24v13 motor driver (on hand since 2026-09-28), behind a 30 A power-cut relay that is closed when unpowered. Feed in by entry 12, 14/2 on its own 20 A breaker (Electronics plan 7.6); motor and feedback out by 13. Encoder A, wind and the Water Witch states arrive on the aft trunk. Chain 1 carries the battery trip. The opto board’s outputs (Water Witch states, release bus readback) and the G2 fault line go to the expander, on the pins that were relay channels 13 to 16. Not fitted: short relays, branch current meters, a VE.Direct reader, gas sensors.
| Nucleo pin | Job | Nucleo pin | Job |
|---|---|---|---|
| D0, D1 | Wind meter in, out (Calypso CMI1018) | D3 | Relay ch 5 coil (release enable) |
| D2, D10 | CAN board TX, RX | D7, D8 | Release gates ch 1, 2 |
| D4, D5 | I2C data, clock (expander, BME280, humidity) | A3, A6 | Release gates ch 3, 4 |
| D6 | Encoder A | A4, A5 | Release gates ch 5, 6 (after the links come off) |
| D9, D13 | Steering PWM, DIR to the G2 | D11, D12 | 1-wire chain 1 (battery trip), chain 2 (air) |
| A0, A1 | G2 current sense, Ewellix wiper | A2, A7 | A2: relay ch 13 coil, the horn. A7: spare |
Before burn-in, take off the four solder links that join A4 to D4, A5 to D5, and A2 and A7 to the USB serial (check the link numbers in the board manual). The G2 needs its terminal blocks soldered on at the bench too.
The charging stop, beside relay 8. Battery positive comes in by entry 22 on its own thin wire from the main bus board’s positive bar, ahead of the branch breakers, through the 1k 1 W resistor at the bar. Never take it off the node’s own feed: a tripped node breaker would then stop all charging. It runs through channel 8’s normally closed contact and back out by entry 22 on one run to the main bus board, where the yellow wires of the five Victron remote on/off cables (ASS030550320) meet, tied together on a joining strip; all five blacks go to battery negative (Electronics plan 6.7). No fuse: the 1k limits a short anywhere on the run to about 29 mA, and a blown fuse there could stop all charging. Coil on (shore command, 5 days at most unless renewed): all five chargers stop. A dead node, expander or feed drops the relay, and so does the node once neither Pi has been heard for the set time. Measure each run to its MPPT against the cable’s own length; if short, extend with 18/2 tinned wire on a screw terminal strip, no solder.
Channels 9 and 10. Channel 9 (camera port UV-C) leaves by entry 27 to the LM317 regulator and the UV-C lights at the camera port: small 275 nm LED boards above and below the lens, starting at 20 mA with a 62 ohm set resistor (the build: Underwater Camera Port Guide). Channel 10 leaves by entry 28 to the Orion-Tr’s remote on/off.
Release. Channels (Electronics sec 4.3): 1 and 2 the drogue lids (horn A here, horn B on Release Node B); 3 to 6 the four cord pullers; 7 to 9 Boat 2; 10 to 15 retired on Boat 1 (Boat 2 keeps one pull-pin); 16 retired. Relay channel 5 and the channel’s MOSFET must both be on, both from native Nucleo pins. The release bus has its own 12/2 feeder (on hand) on a 30 A breaker at the bar (stud 4), not the node’s 15 A feed, entering by its own entry, 2a in Appendix A3. Open: measure the 12/2 jacket, then size this gland and Release Node B’s (PG11 or PG13.5).
Each puller runs through its own DPDT reversing relay (it swaps the motor’s two wires): 24 V coil, 10 A, each in its own DIN socket with screw terminals, coils on channel 11, no coil diodes needed. The 1N5408 sits on the relay input side (MOSFET drain to the release bus), so it works both ways; the horns need none. Ahead of each relay, one slow-blow 5 x 20 mm fuse in a DIN fuse holder, sized at the bench test; each puller runs 64 s and stops. Release is forward only; reverse needs a shore test command, with ch 5 and the puller’s channel still on. Entries 3 and 4 carry two drogue fire pairs (14 AWG) plus four cord puller power pairs on two 18 AWG 4-core cables, one per pair of pullers (Mike, 2026-10-02); which cores ride which trunk is counted when the wires are cut to length at fit-out.
What it is. The battery watchman, bolted to the outside of the battery box’s aft wall and never inside it. It watches and controls nothing: no wire to the chargers, no relay, no load. The SBMS0 reads all eight group voltages through its own nine tap wires, pack current through the 300 A shunt, solar current through the 100 A shunt, and pack temperature (its XT1 thermistor on pins 15 and 16 of its green plug). It streams them to Pi A through the Electrodacus WiFi/USB add-on board (a micro USB socket, its lead tied down right outside the plug) and the USB hub beside Pi A. That stream is required: the battery percentage comes from it, because the SBMS0’s pack shunt is the only battery current sensor aboard. The JK balancer evens out the eight groups through its own nine tap wires; it talks to nothing and controls nothing. No CAN, no RS-485.
Where. Four 1/4 in stainless bolts through the aft wall on the minus side, opposite the main fuse, at mid-height or above, where the inside of the wall faces only the 1.75 in air gap and the aft G10 plate, never the cells; never on a long side wall. Each hole bored oversize, filled with thickened epoxy and redrilled, each bolt bedded in sealant, fender washers inside, nylon lock nuts or blue Loctite; drill before the pack goes in (Battery Box Building Guide Parts 4 and 8). All its glands face down, each cable with a drip loop. It is IP65: spray, not standing water; a drowned BMS box only loses readings.
The SBMS0 side. Its tap wires land on a Winford BRK2X6-L-DIN ribbon breakout board on the DIN rail, fed from the SBMS0’s cell socket by a new 12-pin ribbon about 8 in long; the SBMS0’s own ribbon is not cut. Terminal number = ribbon wire number: W0 on 1 with a jumper 1 to 2 and the 12-core’s shield drain on 2 (the shield grounded at this end only), W1 to W7 on 3 to 9, W8 on 10 with jumpers 10 to 11 and 11 to 12; never more than two wires under one screw. The green plug takes the two shunt pairs (battery shunt on pins 3 and 4, solar shunt on 1 and 2) and XT1 on 15 and 16.
The JK side. Its 11-pin plug carries B0 to B8 and its own power pair, V- and V+ (10 to 40 V). Each harness wire joins a core of its 18 AWG 10-core cable with an adhesive heat-shrink crimp butt splice: at W0 the B0 and V- wires share one end of the splice, at W8 the B8 and V+ wires. Splices staggered and tied to the plate; the board still unplugs at its own plug. Set it up by phone over Bluetooth: LiFePO4, 8 cells.
Entries. Entry 1 carries the eighteen tap wires (the SBMS0’s nine and the XT1 pair on 11 cores of the 22 AWG 12-core shielded cable, the JK’s nine on its 18 AWG 10-core), and the DS18B20 chain, sleeved in adhesive-lined heat shrink so the gland seals on one round sleeve; the chain leaves by its own PG7, entry 6, to central node entry 18. Open: entry 1’s gland, PG13.5, PG16 or PG21; measuring the sleeved bundle settles it. Both shunts sit on the positive side of the main bus board, and only their sense leads come in, by entry 3: one twisted pair per shunt, each wire on a 30 AWG fuse link at its shunt end, since it sits at battery voltage. Powered from the pack per the SBMS0 manual. No humidity breakout (no reader in this box).
Monitoring only. No EXTIO4 wiring, no charge bypass, and no VE.Direct remote cables (they leave from the central node, Sheet A3 entry 22), so entries 2 and 5 are not drilled. The charge limits live in the five MPPTs’ own lithium profiles (27.6 V absorb, 27.0 V float, temperature compensation off). Nothing stops charging in the cold automatically: Pi A alerts shore below 33 F on any pack probe, and shore can send the 5-day charging stop (relay channel 8).
FSESC box: deleted, neither boat. Number kept so later numbers stay put.
What it is. The plastic aft junction box is a patch panel, not a computer: the post’s wind and light cables and the deck sensors land on DIN terminals with one fuse per post feed, about 14 entries (15 if the second trunk is drilled), plus the vent; measure the box before the wires are cut to length. It holds no network parts. Beside it sits the aluminum network switch box (Sheet A6a), which takes every network cable; the Ethernet surge protectors are on their own board near the deck (also Sheet A6a). The entry numbers are kept, so entries 1, 2, 6 to 8 and 20 to 24, which moved to the switch box, are not drilled here.
Open: the switch’s 24 V feed. The switch stays on the always-on house branch. Whether its 24 V is a short jumper from this box’s feed terminals to the switch box’s entry 10, or its own run from the main bus board, is still to settle; the dashed stub at the left of the drawing marks it.
Post and cables. The post carries exactly four cables: two cameras, wind, lights. The wind and light cables come into this box (entries 3 and 4); the two camera Cat6 runs go through the surge board to the switch box (Sheet A6a). AIS is below deck. Entry 5 is plugged: no weather pod. The post wind meter’s 5 V regulator (Pololu D36V6F5) sits in this box, just after the wind sensor’s fuse; it gets its terminal block at a workbench, then it is potted.
Switched power. Everything switched arrives from the central node on six 16/2 duplex runs through two PG13.5 glands: Starlink power (relay channel 1), the wet lab’s own line (2; it reaches the central node from its own 15 A breaker, by entry 29 there), the nav lights (3), the em-trak (4), the bilge pump 1 manual-on (6; pump 2’s, channel 12, rides a 16/2 run or the sensor trunk) and the motoring-white coil (7). The TSW202 is on no channel. The nav lights arrive already switched, on channel 3’s normally closed contact, lit from sunset to sunrise and by day too in fog mode: a dead node leaves the boat lit, and the node lights them by itself if neither Pi is heard for the set time. There is no photocell relay. The motoring whites add on through their own 30 A relay here, its coil on channel 7: on only when it is dark and the motor runs, and in fog mode whenever the motor runs.
Sensors. The two bilge Water Witch states ride the trunk to the central node’s opto board. Pump running is known from the Water Witch 24 V output, so the central node’s current-meter entry 17 is not drilled. There is no high-water sensor. One sensor trunk is likely enough (two Water Witch states, two manual-ons, encoder A, wind); count at fit-out.
Fit-out flag. Lighting leaves this box three ways in the schedule (post lights cable 4, lights group 11, the bow lantern feed 19). Settle the split, and where the stern light’s feed actually rides, when the wires are cut to length; relay channel 3 at the central node switches all of the nav lights either way.
What it is. The network switch box is a CXCESNS aluminum box, the same as the two compute boxes, beside the plastic aft junction box (Sheet A6) at the stern. Every network cable ends here: nine bulkhead jacks (RJ45 couplers; a tenth only if SFP 10 is used), the 24 V feed and a vent, about 10 entries in all. It holds only the TSW202 switch, its Mean Well supply and the SFP module: nothing lightning-related. Keep the box well above bilge water.
Mounting inside. The switch and its supply clip to a DIN rail on a long side wall, not glued to the floor: the TSW202 is 4.8 in (122 mm) deep and the box only 3.9 in. On the side wall the switch reaches about 4.8 in across the 8.3 in floor, plus about 1.2 in of plug, which leaves about 2.3 in to turn the patch cords. Heat goes from the rail to the box wall, the glued face and the hull: about 5 to 15 W in all. Right-angle patch cords at the switch ports (a short right-angle adapter at a port is fine where a straight plug cannot turn), each cord tied down within about 2 in of its plug. Open: which way the right-angle plugs must point; reading it off the switch, with the distance from the rail to the port face, settles it before the cords are ordered.
Wall jacks. Every network cable crossing a box wall comes in on a bulkhead jack, one per cable: the Alrhso panel couplers, zinc and plastic (fine on Pi B’s UTP run: its metal touches no wire or shield). The outside face sits in the hull’s salt air, and the jack’s cap seals only an empty jack. On each outside face: a thin smear of dielectric grease on the plug, plug in, then self-fusing silicone tape stretched to about twice its length, half-overlapped, from the jack’s threads over the plug and 1 to 2 in down the cable, with no gaps, and a drip loop below. Jacks go on side or bottom walls, facing sideways or down, never on the top (the drawing puts them on top only for clarity). Inside faces, within sealed boxes, need no tape. The same goes for the one jack on each of Pi A, Pi B, the Starlink enclosure and the light driver’s dry box: 13 in all.
The switch. The five camera runs, the PoE light driver, Pi A, Pi B and Starlink all meet the Teltonika TSW202 (8 PoE ports plus 2 SFP slots; PoE is power sent down the network cable). Port map: on the drawing. The switch is always on from the house branch, never on a relay: shedding it would blind Starlink and cut the Ethernet between the Pis. Cameras and lights save power by per-port PoE control through the switch’s Web API, read back over SNMP, firmware pinned. PoE budget on the 112 W Mean Well supply: cameras about 60 W set aside, plus the driver at 25 W (802.3at) or 12 W (802.3af); both fit, no supply upgrade.
Surge protectors: on their own board near the deck, in neither box. The five deck and near-deck cables (two post cameras, foredeck fisheye, interior camera, Starlink) each pass a Ubiquiti ETH-SP-G2 (outdoor-rated) on a small board on a bulkhead where they first come inside. Their grounds go to one small tinned bar; one 6 AWG lead runs short and straight from it to the lightning copper, a foot or two at most (Lightning Guide 6.2, 7.4). Open: where the copper runs near that bulkhead, and so which bulkhead takes the board; check at the boat. Short premade Cat6 runs go down to this box’s wall jacks, low in the hull; keep cables before and after the protectors apart.
Network cables are premade, none crimped aboard. Extra coiled near the surge board (small tight strapped coils about 8 in across, the camera side and the switch side apart); none in this box: 6 in to 1 ft patch cords, jack to port. No sharp bends at plugs; check each plug passes its holes and glands, or use a split gland (a gland that opens to close around a cable that already has its plug).
Open: the switch’s 24 V feed stays the always-on house branch; whether it is a short jumper from the plastic box’s feed terminals (Sheet A6 entry 9) or its own run from the main bus board to entry 10 is still to settle.
Cooling. This box is glued by its back face straight to the hull in the heat-carrying epoxy of Compute Bay 2.3, like the Pi A box; entries go on the other faces, with drip loops. It is wired to nothing and stays off the lightning copper list (Lightning Guide 6.2).
What it is. Main propulsion drive for the ME1616 motor: the Flipsky 75200 Pro V2.0, aluminum PCB, power-button variant, bought 2026-10-03 on Amazon (order 114-2434294-4539414), $160.99, here 2026-10-07; the 2026-09-05 PayPal order shows no payment, and if it turns up too, one goes back. A crimped shorted plug replaces its on/off button, so the board runs whenever battery is present. No precharge (Mike, 2026-09-29): the battery switch makes the first connection. Boat 1 sails with this one VESC; VESC B (Sheet A8) is Boat 2 only.
Plugs. COMM: JST-PH 8-pin, pairs on hand. CAN: JST-GH 5-pin leads, on hand (Kidisoii pre-crimped kit); CANH, CANL, GND only, PWR.ON open. Pin 1 found by meter at the bench check.
Eight holes. CAN; UART + kill; battery + and − (PG16 each, in through the TVS); three phase legs (PG16 each, drawn as one run) with the single 1.0 in mix-31 clamp over all three just outside the wall; sensor lead. Pi A holds a direct UART line with a hardware kill beside the CAN drop; the kill line is the hardware backstop under the jam logic in the Pi.
Motor sensor. The ME1616 sensor harness is built to the Sep 2 spec (crimp, no solder; SinCos encoder input). A 10k and 18k divider on sin and on cos, unless the bench check shows the tops stay under 3.2 V. The motor’s sensor plug is an Aptiv Metri-Pack 150, 8-way, sealed; its mating plug (an ELITE.CITI pair with terminals and seals for 20 to 22 AWG, $14.81) is ordered. Motor temperature sensor: KTY84/130; check the board has the 10k resistor the firmware assumes.
Power and cooling. Extra bus capacitance sits at the controller: four Nichicon 1,000 uF 63 V on a small G10 board on two insulated MGI SpeedWare 3/8 in posts, where the 2 AWG feed and the controller’s own 8 AWG leads land (Electronics plan A7). The Flipsky sits on an aluminum plate through the box floor, set in the heat-carrying epoxy and wired to nothing. Size the plate before the box is drilled, and check it against Lightning Guide 6.2’s one-connection rule.
Boat 2 only, not fitted on Boat 1. Boat 1 sails with one VESC: losing propulsion costs time, not the trip, because the wing sails the boat. The backup VESC, the phase-transfer contactor, its set and reset coils and position sense are Boat 2 parts; no holes are drilled for this box on Boat 1. On Boat 1 there is one throttle path and the “propulsion_backup” software state is unreachable.
On Boat 2. The backup throttle: a 40 A class VESC on the house bus, feeding the same motor through the phase-transfer contactor, which picks whose phases reach the ME1616. The contactor coil is fed from the main bank (island rule); the set, reset and sense lines pass through this box’s terminals. House bus by design: with VESC A and the Electrak on control and VESC B on house, no single bus failure strands both throttle paths.
Holes. Seven, Boat 2 only (the Appendix A8 text says 8, but its own list adds to 7).
What it is. Dumb by design: cells and sensors only. Every board that thinks lives next door in the BMS box. No CAN drop, no stop-wire relay, no data isolator at the box. Five holes, plus the main fuse’s bolts and the BMS box’s four bolts (M). Dashed circles on the drawing are holes that are not drilled.
Aft wall, high. Two PG16 (7/8 in) for the 2 AWG mains, in line with the terminal posts at measured post height so the cables run straight over the aft end plate. One gland for the signal bundle: eighteen tap wires, nine for the SBMS0 and nine for the JK, the XT1 thermistor pair and the DS18B20 chain. Open: that gland, PG13.5, PG16 or PG21; measuring the sleeved bundle settles it (Sheet A4). The Gore vent M12 (1/2 in) as the breathing inlet. Aft wall, outside, mid-height on the + side: the 300 A main fuse (F); bed any bolt through the wall in sealant. Opposite it, on the − side at mid-height or above: the BMS box (M), four 1/4 in stainless bolts, each hole bored oversize, filled with thickened epoxy and redrilled, each bolt bedded in sealant; drill before the pack goes in.
Forward wall, high: the relief stub. A 2 in hole-saw opening with a 1-1/2 in Sch 40 PVC stub glassed through, pointing up at 45 degrees into open cabin space. Inside it, a Dometic/Sealand 1-1/2 in toilet duckbill (OEM 385310076), lips out, flange clamped by a PVC coupling, discharge aimed forward away from the electronics. No screen on the stub: the duckbill is shut except when the box vents, and the cell-temperature trip is the protection. Not fitted: a bug cap or a fine flame mesh. None of these either: burst membrane, overboard duct, transom hole, flame screen.
No heaters. No pads, thermostats, thermal fuses or their wiring. Nothing stops charging in the cold automatically: no stretch of the route has a monthly-mean sea temperature below 35 F, the pack follows cabin air on its 2 in foam, and Pi A alerts shore below 33 F on any pack probe, so shore can send the 5-day charging stop (relay channel 8, Sheet A3).
Heat trip; no gas sensor (do not re-propose). The six DS18B20 pack probes carry the trip: 150 F on any probe, or a 10 F rise in five minutes, isolates the bank, HIBERNATE, alert. Release after one hour with every probe below 120 F. Warning-only alert at 131 F.
Taps. Each board has its own nine tap wires, each on its own ring and its own 30 AWG fuse link at the terminal end: 18 rings and 18 links, the two wires of each joint on two different posts of it. The bundle rides thick adhesive heat shrink at the gland pass, splits just inside into one branch per stack, and each branch is held by nylon cable clamps on short wood screws into the long wall, never tied to the cells. Build details: Battery Box Building Guide Part 8.
The island’s own 24 V: a bought Dyness 24V 100Ah LiFePO4 (25.6 V, 2,560 Wh) in its own plastic case, with a built-in 100 A BMS, bought instead of a team-built 8 × EVE LF50 bank. No box is built and no gland is drilled: the compartment is the enclosure, and every wire lands on the battery’s M8 (5/16 in) posts or on a small fused DIN strip beside it. No hole schedule and no gland list (Electronics and Wiring Plan A10). The inline 30 A ANL, within a few inches of the positive post, protects the cable.
Two loads (Pi B and Iridium B) and two chargers. The SmartSolar 75/10 charges the bank from its two 50 W panels, even with the main bus or the node dead. The Orion-Tr 24/24-5 isolated charger (output 27.0 V) runs from the main bus 90 minutes a day and after the monthly exercise, switched through its remote on/off terminal by central node relay channel 10 on its normally open contact, so a dead node leaves it off. Its transformer is the only link to the main bank. Open with the maker: whether the built-in low-temperature cutoff blocks charging.
Voice number one. RockBLOCK 9603 on its carrier, fed always on from the main bank through an isolated 24 to 5 V converter (its 5 V side has no wire connection to its 24 V side) and a TVS. Isolated because the stub arrestor ties the coax shield to the lightning copper: the tie stops at the Iridium side, and the main negative is not tied to the copper a second time. The converter (Claude’s pick, 2026-10-09): a Mean Well DDR-15G-5 on a short DIN rail on the mounting plate, 9 to 36 V in, 5 V 3 A out against the RockBLOCK’s 0.5 A at most, 4,000 V between input and output; it stands about 2-1/2 in off the plate. The box: a TICONN IP67 ABS box, 5.9 x 5.9 x 3.5 in, with its mounting plate. Its idle draw is not published. Serial to Pi A (the ADuM isolator sits inside Pi A’s box); coax straight to the quarter-wave stub.
Feed: a 5 A breaker on its own stud at the main bus bar, 16/2 (Mike, 2026-09-28: a breaker comes back after a passing fault; a fuse would leave the voice dead). Coax: the stub arrestor is the only protection (no safing relays; a stub cannot wear out). It lands on the underside of the post’s copper deck terminal, a few inches from the deck stub. The coax comes below through the post’s 1 in deck stub with the GPS and Starlink cables. Antenna: on the aft deck beside the post, under its own clear acrylic dome on a white base plate, rubber gasket, with a 5/64 in (2 mm) weep hole at the low point (Instrument Post Guide 11.1; Electronics 6.5). The dome goes where no solar panel shades it and where it shades no panel.
Voice number two, the same inside but living entirely on the island: emergency-bank power, serial to Pi B through Pi B’s isolator, its own stub and dome. Its isolated converter keeps the island’s floating negative off the lightning copper, which the stub arrestor ties to the coax shield. The converter and the box are the same as Iridium A’s (Sheet A11-A). Nothing is shared with Iridium A, on purpose: a fault that silences one voice cannot reach the other.
Feed: fused on the emergency bank’s small fused DIN strip (Sheet A10). Antenna: forward on the foredeck under its own clear acrylic dome, built like Iridium A’s, with the same 5/64 in (2 mm) weep hole. Its coax comes below through its own small deck hole, so the two chains share no dome, deck hole, cable or fuse (Build Guide 8.3). The dome goes where no solar panel shades it and where it shades no panel. Arrestor lead: 6 AWG wire, about 6 to 7 ft aft to the lightning junction; measure where it lands before cutting the wire.
One board, one hole. The AS3935 lightning detector hangs off WD-B on a short 7-core lead that carries its power and its data; inside the Pi B box the lead passes a 4-channel two-way level shifter (the detector works at 3.3 V, the Nano at 5 V). It logs strikes; WD-B never cuts Pi B’s power for lightning. The box touches no metal and is glued to a pad glued to the boat.
Open: bench the false-trigger rate with VESC A running before trusting it here. The fallback is a small forward node with an isolated transceiver.
The broadband dish in its deck enclosure. Ethernet runs to the TSW202 at the aft junction (SFP port 9 through a copper SFP module), a long Cat6 run to the stern; its bulkhead jack’s outside face is greased and taped (Sheet A6a). Power rides relay channel 1 from the central node, so the Pi can shed it or power-cycle it. No enclosure heater: the dish has its own snow-melt heater. Declared sacrificial: no arrestor; losing it costs bandwidth, not the boat.
Deck hole: the instrument post’s 1 in PVC deck stub. The post bundle and the Starlink, GPS and Iridium A cables come below through that one stub and its 1 in liquid-tight flex conduit; no separate standpipes. Only Iridium B keeps its own small deck hole, under its forward dome, so the two satellite chains share no hole. Pass the bundle through a sample stub on the bench before the real one is glassed in; make up the coax connectors after the cables are through.
What it is. Bought devices with their own sealed housings and connectors: no box of ours, no holes of ours. Each takes a tee on its backbone and a cut-cable drop into its own connector. The Ewellix CAHB-22 has no bus: its cable runs to the central node (Sheet A3, entries 12 and 13). The Electrak HD tee is Boat 2 only.
The wing (Wing Power System sec 1A). It reaches the hull through a sealed slip ring in the can (sliding contacts that pass wires across a turning joint), and its wires land in a new small wing box below the deck, where the wing's wires enter the hull. Eight ring wires: the Electrak MD’s 24 V and CAN pairs, the tip meter’s RS-485 pair and the wing compass’s RS-485 pair (on the ring’s two spare power rings). At the tip the 24 V pair feeds a branch on its own 1 A inline fuse: the compass runs on that 24 V (9 to 36 V), and a small converter makes 5 V from it for the tip meter alone (never 24 V on the meter). The compass (WitMotion HWT905, on the tip cap) gives the wing’s turn rate and, against the hull’s heading, its angle; there is no angle sensor in the can. The ring’s fixed-side cables leave the can by its wall gland and go down through their own deck gland straight into the wing box below the deck (Mike, 2026-10-02), where each ring wire gets a fuse or surge part (three Taidacent modules and the 24 V pair’s 5 A fuse and 1.5KE33CA), so a mast strike stops there. Nothing in the wing box thinks: one shielded 4-pair cable runs on to the USB hub box beside Pi A (Sheet A1a), carrying the actuator’s CAN pair, the tip meter’s and the compass’s RS-485 pairs, each after its surge module, and a ground pair tied to the wing’s 24 V negative in the wing box (the isolated readers’ signal side floats, so it must share a reference with the sensors). The cable is any shielded Cat6, all copper, with a shield over all four pairs, plugs cut off (Mike, 2026-10-09; Wire and Cable Buy List C8): blue the CAN pair (CAN H solid blue, CAN L blue-white), orange the tip meter’s RS-485 (A solid, B white), green the compass’s RS-485 (A solid, B white), brown the ground, both wires together; same colors and labels at both ends. Its shield is grounded at the wing box end only (Mike’s OK, 2026-10-09): the braid (or drain wire) twisted into a short pigtail, sleeved in heat shrink, on the box’s 24 V negative terminal, where the brown pair and the three Taidacent modules’ ground terminals also land (each module’s ground goes to that negative, as the battery bus surge modules’ do, so the boat keeps its one bond wire); any pair foils folded back and trimmed. At the hub box the shield is trimmed back flush and sleeved, touching nothing. The strike comes in at the wing box, so the shield drains there; grounded at the hub end it would carry the surge into the box beside Pi A, and grounded at both ends it would close a loop through the boat’s wiring. There the Waveshare 2-channel RS-485 reader takes the tip meter and the compass, and the DSD TECH SH-C30G isolated USB to CAN adapter talks to the actuator on its own lead to Pi A. RS-485 terminators off. The wing’s program runs on Pi A. The ring is the Rion HC2549, paid $495 (Mike, 2026-10-01).
The wing box’s wall: in, its 24 V feed (16/2 on its own 5 A breaker on the branch bar, then the box’s own 5 A fuse); in, the hull cables from the slip ring; out, the cable to the hub box. Open: the box’s material, whether it takes a vent, and each entry’s gland; picking the box and the cables settles them. Open: how many hull cables carry the ring’s eight wires; the cable choice settles it. Open: which stud feeds it, the end stud or stud 3; Mike’s call settles it.
What it is. The backup for the central node’s releases. Its own fuse, its own enable relay, its own MOSFET pairs and the same two-condition lock, commanded over the house bus, so no single bus or box failure silences every release. No shorting relays and no opto board: four entries (CAN, 24 V, drogue 1, drogue 2) plus the vent, and five Nucleo pins; entries 5 to 8 are not drilled. It releases the horn-B channel of each drogue box; either node alone cuts a drogue strap.
Same rules as the central node. Unpowered, it cannot release. Two separate conditions: the enable relay closed and the channel MOSFET on. No humidity breakout; no ferrites. No short relays, no opto board, no continuity or confirm readback. The monthly enable relay exercise covers this node.
What makes it independent. Five separate layers; a fault has to cross all five to take both paths to one device. Different bus: the central node is on the control backbone, this node on the house backbone, each with 12 V on its pair, fed once from its own 5 A breaker at the main bus board and its own 24 to 12 V converter at the compute multiport, with its own tees and terminators. Different power: a house-side branch with its own fuse. Different parts inside: separate Nucleo, firmware instance, converter, enable relay, release bus and MOSFET modules. Different holes and routes: its cables leave through their own glands and travel a different path to the same device, so one chafe point cannot take both paths. Different half of the device: each drogue lid carries two channels (horns A and B), and either one alone does the job. Still shared: Pi A, which commands both, and the main bank, which feeds both.
What the two conditions are. Not two brains agreeing, but one brain doing two physically separate acts: close the enable relay, the only thing that puts 24 V on the release bus, and turn on that channel’s MOSFET, the only return path to ground. Idle, the release bus is dead metal and the return is open. An enable timer drops the bus again if a release command never arrives. That defeats a welded contact, a shorted MOSFET, a stray 24 V wire landing on a release terminal, or a wet terminal block. It does not defeat a Nucleo gone haywire, which is why the drogue and JSD paths also need a signed ground command and have no automatic path at all.
The honest cost of the split. Two chains double the odds a lid opens when it must, and double the number of boxes that can open it when it must not. What holds that second risk down is the signed ground command and the enable timer. There is no idle short across the burn wires: the dead release bus and the open MOSFET are the two conditions.
What it is. A DIN strip in a box, nothing more. The central node’s two release trunks land here and fan out to the drogue boxes and the JSD cord pullers ×4 (24 V worm-gear motors, one per T8 trigger). The aux-rudder release is Boat 2 only and unwired; there are no pull-pin stations. No electronics, so nothing to fail.
Why it stays passive. Like the aft junction, a box death here is a wiring fault, not an electronics fault, and every conductor can be checked at the strip. Each conductor gets one landing and a label at both ends, so a stern fault is found with a meter at the strip instead of by pulling a trunk. The fuses stay forward at the central node end of the trunks, so nothing in here can fail while powered. Chafe-sleeve the trunks where they enter, drip loops on everything, no ferrites.
What it buys, and what it costs. Nothing electrical. It turns four long runs from the central node (forward, by the battery and the busbars) into two trunks plus four short tails, and keeps about two holes out of the central node wall. The cost: two extra screw joints on every conductor, in a plastic box on the transom, on the one circuit where a bad joint cannot be recovered. Whether that is worth it comes down to the trunk core count, still open in Pending Amendments. The trunks carry the two drogue fire pairs plus four cord puller power pairs, about 12 cores (the puller reverse is done inside the central node, so it adds no wires aft). At twenty-plus conductors the trunks clearly win; at a dozen, direct runs are competitive and the joints go away. Compare Sheet A15, which runs direct to the same stern devices with no strip in between.
What it shows. For every releasable device: which chain can release it, and what has to die before nothing can. Solid lines are the node-A chain on the control bus, through the passive transom strip. Dashed lines are the node-B chain on the house bus, running direct.
The main point. The two drogue lids have two chains; the JSD cord pullers ×4 (24 V worm-gear motors, one per T8 trigger) do not. The pullers are driven only by the central node and reach the stern only through the transom terminal box, so the trunk, the strip and the node are three single points in series. A second path for them would need four more channels and new runs to the stern. They can be run backward for testing from shore through relay channel 11 (Sheet A3).
Channel numbers are owned by the Electronics and Wiring Plan sec 4.3: 1 and 2 the drogue lids (horn A central node, horn B Release Node B); 3 to 6 the four JSD cord pullers (central node); 7 to 9 reserved for the Boat 2 aux rudder (unwired); 10 to 15 retired on Boat 1 (Boat 2 keeps one pull-pin); 16 retired (trim decouple, not on this sheet). Pi A commands both chains, so the Pi and the main bank are the two things this split does not protect against; everything after them is doubled for the two drogue lids.
| Device | Path A | Path B | If one chain is lost |
|---|---|---|---|
| Drogue lid 1 | Central node ch 1, trunk, transom strip, entry 3 | Release Node B, direct, entry 3 | Either channel alone cuts the strap |
| Drogue lid 2 | Central node ch 2, trunk, transom strip, entry 4 | Release Node B, direct, entry 4 | Either channel alone cuts the strap |
| JSD cord pullers ×4 | Central node ch 3 to 6, trunk, transom strip, entries 5 and 6 | none | No release: node, trunk and strip are all in series |
| Aux-rudder release, Boat 2 only, unwired (ch 7 to 9 reserved) | Central node ch 7 to 9, trunk, transom strip, entry 7 | none | No release: same three in series |
| Pull-pins (ch 10 to 15) retired; bridle switches deleted, entry 10 plugged | |||
Path A entry numbers are Sheet A16 entries; Path B entries are Sheet A15 entries. Release Node B has no opto board and no short relays: four holes and a vent.
The open questions that touch the wiring live in one place, Pending Amendments v10.3 (the open list). On these sheets they are:
Boxes and glands. The USB hub box itself (to buy: its material, and so whether it takes a vent) and the gland for each of its entries (A1a). The wing box’s material, vent and glands, and how many hull cables carry the slip ring’s eight wires (A14). The battery tap bundle’s gland at both ends, PG13.5, PG16 or PG21, once the sleeved bundle is measured (A4, A9). The release feeder glands, PG11 or PG13.5, once the 12/2 jacket is measured (A3, A15). The aft junction box size (A6).
Feeds and parts. Which bus bar stud feeds the hub box and the wing box, the end stud or the stud table’s 8 and 3 (A1a, A14). The emergency bank DIN strip’s fuse sizes for Pi B, Iridium B and the 75/10 (A10). The switch’s 24 V feed, a jumper from the aft junction or its own run (A6, A6a). The SBE 45’s serial type, RS-232 or RS-485, read off its label on arrival (A1).
Routing and fit. Which way the switch’s right-angle patch cords must point (A6a). Which bulkhead takes the network surge board, near where the lightning copper runs (A6a). The aluminum cooling plate through the VESC A box floor (A7). The camera port’s UV-C lights (a factory-made board, or the small boards on trial). Which release trunk carries which cores (A3, A16). The lighting exits at the aft junction (entries 4, 11 and 19 all carry lighting).
The decided items are drawn in on their sheets.